IPMI OEM 命令索引集合
更新时间: 2026/06/11
在Gitcode上查看源码

IPMI OEM 命令索引集合

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/09初稿,IPMI OEM自定义命令索引
25.062025/06/27增加命令 Write MAC Address 详细链接
25.122025/11/07增加 OEM 部分命令索引和详情链接

装备类命令(Cmd:90h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Write MAC Address30h90h00h
Read MAC Address30h90h01h
Physical Led Test30h90h02h
Clear E lable Data30h90h03h
Write E lable Data30h90h04h
Read E lable Data30h90h05h
Update E lable Data30h90h06h
Get E label Reservation ID30h90h07h
Read Version Data30h90h08h
Start Device Test30h90h09h
Get Device Test Result30h90h0Ah
Start IPMB Test30h90h0Ch
Read Video Data30h90h10h
Set Serial Port30h90h12h
Get Handle State30h90h13h
Reset FRU30h90h14h
Set Ethernet Mode30h90h15h
Get Ethernet Mode30h90h16h
Get DFT Mode30h90h1Fh
Set DFT Mode30h90h20h
Set Global Configurations30h90h21h
Get Global Configurations30h90h22h
Start Port Test30h90h25h
Get Port Test Result30h90h26h
Regenerate Device GUID30h90h27h
Set Keyboard Value30h90h28h
Get Component Info30h90h29h
Dft Get System Health30h90h2Ah
Dft Get System Health Event30h90h2Bh
Dft Get Component Properities30h90h2Ch
Get Dft Interface Version30h90h2Dh
Read Version Release Date30h90h30h
Get test type30h90h31h
Set Test Count30h90h31h
Get Test Count30h90h32h
Set Target level30h90h33h
LCD Test30h90h34h
Get Chip Status30h90h35h
Set UFCA UFCB flag30h90h36h
Read UFCA UFCB flag30h90h37h
Set test type30h90h38h
Set BMC IP ADDRESS30h90h3Ah
Get CPLD Register Value30h90h3Bh
Load Device Firmware30h90h3Ch
Get Component Position Info30h90h3Fh
Get DFT Test Item cnt30h90h40h
Get DFT Test Item30h90h41h
Start DFT Test30h90h42h
Get DFT Test Result30h90h43h
Set BMC MAC Address30h90h44h
Get BMC MAC Address30h90h45h
Load Default Setting30h90h46h
Get BMC Net Speed30h90h47h
Get BMC Process Time30h90h50h
Get Chip DIEID Info30h90h51h
Set Chip Info30h90h52h
Get Chip Info30h90h53h
Get Device Health30h90h54h
Get FDM Info30h90h55h
Get RFID Info30h90h56h
Set RFID Info30h90h57h
Set System Event Configuration30h90h58h
Get Global Configurations (new)30h90h59h
Set Lan Switch Loopback Test Mode30h90h5Ah
Get Loadline Parameters30h90h5Bh
Set Loadline State30h90h5Ch
Set Bias Voltage30h90h5Dh
Set PSU Serial Number30h90h5Eh
Get PSU Serial Number30h90h5Fh
Update PSU Serial Number30h90h60h
Set Chassis Location Info30h90h61h
Get Chassis Location Info30h90h62h
Set Cpld Channel30h90h63h
Get Cpld Manufacturer ID30h90h64h
Start Cpld Space Test30h90h65h
Get Cpld Space Test Result30h90h66h
Get Power Rack Elabel30h90h67h
Active TSB License30h90h68h
Set Fru E lable MfgDateTime Length30h90h69h
Get Eye Diagram Test Infomation30h90h6Ah
Get PCIe Eye Diagram30h90h6Bh
Erase Teeos Flash30h90h70h
Set Component Customization Infomation30h90h71h
Get Component Customization Infomation30h90h72h
Set Hardware Registers Information30h90h73h
Set System LockDown Status of Multiple Nodes30h90h74h
Get LockDown System Id of Multiple Nodes30h90h75h
Get Bios Allowed Package Type30h90h76h
Set Bios Allowed Package Type30h90h77h
Set DDR Test Configuration30h90h78h
Get DDR Test Result30h90h79h
Set SoC Environment Variable30h90h80h
Get SoC Environment Variable30h90h81h
Dft File Action30h90h82h
Clear Cpld Space Test Result30h90h83h
Get Cpld Space Test Result Information30h90h84h

通用类命令(Cmd:91h)

BIOS 类命令(Cmd:92h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Set CPU Tcontrol30h92h01h
Set BIOS Version30h92h02h
Update BIOS status30h92h03h
Write SMBIOS Data30h92h04h
Set Device Status30h92h05h
Get Device Status30h92h06h
Set HBA Card Configuration30h92h07h
Get HBA Card Configuration30h92h08h
Write File to BMC30h92h09h
Read File From BMC30h92h0Ah
Set File Changed30h92h0Bh
Get File Changed30h92h0Ch
Get CPU Reading30h92h0Dh
Get iMana OEM Revision30h92h0Eh
Add Syslog Entry30h92h0Fh
Set Desired Fan Speed30h92h10h
Get System Restart Cause oem30h92h11h
Set Upgrade ROM SKU Number30h92h12h
Set thermal enforce policy30h92h13h
Get thermal enforce policy30h92h14h
Set System Information30h92h15h
Get System Information30h92h16h
Set FDM Info30h92h17h
Set FDM errinfo30h92h18h
Get BIOS File Property30h92h1Ah
Get Ras Mission30h92h20h
Get Fault Diagnostic Information30h92h21h
Get Hardware Registers Information30h92h22h
Close USB Mass Storage30h92h25h
Create USB Mass Storage30h92h25h
Get USB Mass Storage Status30h92h25h
Set Cooling Policy30h92h26h
Get Cooling Policy30h92h27h
Set NetCard Port Status30h92h28h
Get NetCard Port Status30h92h29h
Set DIMM Info30h92h2Ah
Get DIMM Info30h92h2Bh
Set VRD Parameter30h92h2Ch
Get VRD Parameter30h92h2Dh
Get Dynamic Configuration SMI Command30h92h2Eh
Set Dynamic Configuration Result30h92h2Fh
Get age test flag30h92h30h
Set age test flag30h92h31h
Age test start report30h92h32h
Get age test process rate30h92h33h
Set age test process rate30h92h34h
Age test result report30h92h35h
Get age test result30h92h36h
Get Memory Soft Isolation Address30h92h38h
Clear Memory Soft Isolation Address30h92h39h
Get Hard Isolation Address30h92h40h
Set Hard Isolation Address Results30h92h41h
Set Get MSP switch30h92h42h
Set Get Cached BIOS Upgrade Mode30h92h43h
Set Chip Bitwidth30h92h44h
Get Name of BMC30h92h45h
FDM Record Count Operate30h92h46h
Update BIOS Password30h92h47h
Set PPR Result30h92h48h
Get Row Fault Isolation Address30h92h49h
Set TEE OS Version30h92h4Ah
Get Device Present Status30h92h4Bh
Get Smart Provisioning Info30h92h4Ch
Set Smart Provisioning Info30h92h4Dh
Get Device Capabilities30h92h4Eh
Set Device Capabilities30h92h4Fh
Report Trusted Module Info30h92h50h
Get BMC Two Factor Auth State30h92h51h
Set BMC Two Factor Auth State30h92h52h
Set BIOS Firmware Version30h92h53h
Get BIOS Firmware Version30h92h54h
Get BCU diagnosis data30h92h55h
Set Host Standard Digest30h92h57h
Get Host Digest Result30h92h58h
Get TPCM Measurement Status30h92h59h
Get Smbios Info30h92h5Ah
Set SMBIOS Info30h92h5Bh
Get Bios Boot Info30h92h5Ch
Set Bios Boot Info30h92h5Dh
Set Smbios ext Info30h92h5Eh
Get CPU Capabilities30h92h5Fh
Set DIMM Manufacturer Info30h92h60h
Get Trusted Module Info30h92h62h
Get CE Storm Info30h92h64h
Report Memory Fault Isolation Address30h92h65h
Get Memory HPPR Address30h92h66h
Set Power Capping Attribute30h92h67h
Set PCIe Card BDF30h92h68h
Set PCIe Disk BDF30h92h69h
Get OS Energy Information30h92h6Ah
Set OS Energy Information30h92h6Bh
Set System Parameters30h92h6Dh
Get System Parameters30h92h6Eh
Set OCP Card BDF30h92h70h
Get CPU Lifetime ECCFault Count30h92h71h

通用类命令(Cmd:93h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Send Trap Event30h93h01h
Get Sensor Name oem30h93h02h
Get Screen Snapshot30h93h03h
Set Authentication Key30h93h04h
Set IPMC Configuration30h93h05h
Get IPMC Configuration30h93h06h
Set Mgnt Configuration Recover Point30h93h07h
Recover Mgnt Configuration30h93h08h
Get Sensor Max Event Severity30h93h09h
Set Web Auth Code30h93h0Bh
Get User Group Configuration30h93h0Ch
Set User Group Configuration30h93h0Dh
Set Fan Speed30h93h0Eh
Set Service Configuration30h93h0Fh
Get Service Configuration30h93h10h
Get Power Statistic30h93h11h
Clear Power Statistic30h93h12h
Set Power Capping Configuration30h93h13h
Get Power Capping Configuration30h93h14h
Set Alert Configuration30h93h15h
Get Alert Configuration30h93h16h
Get Log Entry Size30h93h17h
Get Kinescope Bits30h93h18h
Set Kinescope Bits30h93h19h
Get Power Supply Info Configuration30h93h1Eh
Get SOL Blackbox Data30h93h1Fh
Get Desired Speed30h93h20h
Get Local User password complexity check Enable30h93h21h
Set Local User password complexity check Enable30h93h22h
Get Upgrade ROM SKU Number30h93h23h
Set Power Saving Configuration30h93h24h
Get Power Saving Configuration30h93h25h
Get total Temperature30h93h26h
Get Device Info30h93h27h
Get Sensors Info30h93h28h
Set SNMP MIB Configuration30h93h29h
Get SNMP MIB Configuration30h93h2Ah
Set Power Supply Info Configuration30h93h2Dh
Set Access Rule Configuration30h93h2Eh
Get Access Rule Configuration30h93h2Fh
Partial Write E lable30h93h2Fh
Get BMA State30h93h30h
Get Threshold Sensor Reading30h93h31h
Set RAID Parameter Command30h93h34h
Set Property Value Common Command30h93h35h
Get Property Value Common Command30h93h36h
Get Property Value For All Object Common Command30h93h38h
Clear Event30h93h39h
Get Hdd Plug Cnt30h93h3Ah
Get Fruid Info30h93h3Bh
Set Device Info30h93h3Ch
Get Storage Configurations30h93h3Dh
Set Storage Configurations30h93h3Eh
Set shied IPMI command30h93h3Fh
Get Device Name30h93h40h
File Effective30h93h41h
Get RAID Parameter Command30h93h42h
Get Device Location Name30h93h43h
Set User SNMP V3 Privacy Password30h93h44h
Set SmartCooling Customized Inlet Environmen Range info30h93h45h
Get SmartCooling Customized Inlet Environmen Range info30h93h46h
Set SmartProvision Deply Info30h93h47h
Get Lisence Info30h93h48h
Set Lisence Info30h93h49h
Set Firmware Firewall30h93h4Ah
Query Black or White List IPMI30h93h4Bh
Get Firmware Firewall30h93h4Ch
Set BoB Channel Type30h93h51h
Get BoB Channel Type30h93h52h
Set Device Action30h93h53h
Get Device Action Result30h93h54h
Get BBU Power Info30h93h55h
Set BBU Power Info30h93h56h
File Action30h93h57h
Set System LockDown Status30h93h58h
Get System LockDown Status30h93h59h
Set BMC Configuration30h93h5Ah
Get BMC Configuration30h93h5Bh
BIOS Post Host Restart Power Off Type30h93h5Ch
Get BusinessPort s BDF and MAC Info30h93h5Eh
Get Lsw Info Parameters30h93h60h
Set Lsw Info Parameters30h93h61h
Get Hdd Power Status30h93h62h
Set Power Status of a Hard Disk oem30h93h63h
Get BMC Auxiliary Firmware Info30h93h65h
Obtaining Device Bit Error Information30h93h66h
Set VNC Configuration30h93h67h
Set Account Interface30h93h68h
File Upload30h93h69h
Set Area Alarm Info30h93h6Ah
Get Product CCDB Info30h93h6Bh
Set Product CCDB Info30h93h6Bh
Deregister Product Arbitration Info30h93h6Bh
Get Product Arbitration Info30h93h6Bh
Register Product Arbitration Info30h93h6Bh
Set Watch Dog Status30h93h6Bh
Check whether the cache package to take effect exists30h93h6Ch
Get Component Fruid By Uid30h93h6Dh
Get Sensor Over Temp Power Off Threshold30h93h6Eh
Get Syslog Server Info30h93h6Fh
Set Syslog Server Info30h93h70h
Set RMCP+ Cipher Suites30h93h71h
Get RMCP+ Cipher Suites30h93h72h
Set Resource Usage Alarm Threshold30h93h73h
Set SNMP Configuration30h93h74h
Get SNMP Configuration30h93h75h
Get Account Service Configuration30h93h76h
Set Account Service Configuration30h93h77h
Ipmi Check Upgrade Channel Health30h93h78h
Get Account Interface30h93h79h
BridgedRequestMessage30h93h7Ah
Screenshot30h93h7Bh
OEM Account30h93h7Ch
Get Valve Information30h93h7Dh
Set Valve Information30h93h7Eh
Set User SNMP V3 authentication algorithm30h93h7Fh
Get authentication algorithm30h93h80h
Set NTP Configuration30h93h81h
Get NTP Configuration30h93h82h
Set LDAP Configuration30h93h83h
Get LDAP Configuration30h93h84h
Get Statistics for Event Subscription Messages30h93h87h
Get Trusted Computing Configurationn30h93h88h
Set Trusted Computing Configuration30h93h89h
Collect Server Information30h93h8Ah
Get BIOS Configuration30h93h8Bh
Set BIOS Configuration30h93h8Ch
Get Asset Management Configuration30h93h8Dh
Set Asset Management Configuration30h93h8Eh
Set Component Parameters30h93h8Fh
Get Component Parameters30h93h90h
Set Watchdog Timeout Limit30h93h91h
Get Watchdog Timeout Limit30h93h92h
Get Trusted Computing Measurement Information30h93h93h
Full Image Update30h93h94h
Get Full Image Update Status30h93h95h
Get Certificate Information30h93h96h

SMM和多节点 类命令(Cmd:94h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Get Blade Configuration30h94h01h
Get Switch Info Parameters Command30h94h02h
Set Switch Info Parameters Command30h94h03h
Get FCoE Port Map30h94h04h
Upload resource to iMana30h94h05h
Download resource from iMana30h94h06h
Set Chassis Number30h94h07h
Get Chassis Number30h94h08h
Get OEM support30h94h09h
Get span slot mapping30h94h0Ah
Get board license30h94h0Bh
Trigger debug info collection30h94h0Ch
Get SOL Dest Number30h94h0Dh
Get SOL Dest Name30h94h0Eh
Get Power Unit Configuration30h94h0Fh
Set Power Unit Configuration30h94h10h
Set Device GUID30h94h11h
Set EXDisk Power State30h94h13h
Set Firmware Active30h94h14h
Set Capacitance Discharge State30h94h15h
Get Disk Present State30h94h16h
Get Cooling Policy record30h94h17h
Get Master SMM ID30h94h18h
Get Cooling Policy state30h94h19h
Get Port Info Parameters30h94h1Ah
Set Port Info Parameters30h94h1Bh
Get Blade Info Parameters30h94h1Ch
Set Blade Info Parameters30h94h1Dh
Set Blade MEZZ Card Present30h94h1Eh
Set Blade Global Configuration30h94h1Fh
Get KVM Parameter30h94h20h
Set KVM Parameter30h94h21h
Get Stateless Compute Parameter30h94h22h
Set Stateless Compute Parameter30h94h23h
Get Shelf Info30h94h30h
Set Shelf Info30h94h31h
Rearm Events30h94h32h
Receive Event30h94h33h
Get Event Management30h94h34h
Set Event Management30h94h35h
Get Event Entry30h94h37h
Get Current Asserted Event30h94h38h
Get auth token30h94h39h
Set BMC Forward30h94h3Ah
SSO User Secondary Authencation Request30h94h3Bh
Get SSO User Secondary Authencation Result30h94h3Ch
Get event descripion30h94h3Dh
Get File Checksum From iMana30h94h3Eh
Destroy SSO Token30h94h3Fh
Get Event Record30h94h40h
Set VNC password30h94h67h
Shelf Device Power State Control30h94h68h
Get Shelf Device Power State30h94h69h
Get Rack Info30h94h6Ah
Set Rack Info30h94h6Bh
Get Chassis Info30h94h6Ch
Set Chassis Info30h94h6Dh
Get System Id30h94h6Eh
6E Get Chassis Status30h94h6Eh
Get Inter Chassis Information30h94h6Fh

SMM和交换类命令(Cmd:95h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Get Upgrade Support30h95h01h
Get Upgrade File Size30h95h02h
Set SAS Configuration30h95h03h
Get SAS DiskInfo30h95h04h
Set Expander ready30h95h05h
Get Port Mapping30h95h08h
Get Stacking Status30h95h09h
Set VLAN IP30h95h0Ah
Get VLAN IP30h95h0Bh
Save Configuration30h95h0Ch
Get NIC Map30h95h0Dh
Set NIC Map30h95h0Eh

SMM内部通信类命令(Cmd:96h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Set CPLD register30h96h01h

限制类命令(禁用)

特定主从限制类命令(Cmd:97h,禁用)

BMC禁止扩展,只能IMU使用,逐渐日落(Cmd:98h,限制使用)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Report Component Faults30h98h05h
Report DDR4 Fault Isolation Address30h98h18h

其他限制类命令(禁用)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Get Components Version Info30h15h15h
Get Info30h40h40h
Set Info30h40h40h
Port Loop Test30hB0hF0h
Get Energy Information30hE2hE2h
Switch Config30hE5hE5h

存储专用类命令(NetFn:32h)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Set Device To Upgrade Ready Status32h01h--
Deliver the Component Upgrade Package32h02h--
Activate the upgrade32h03h--
Reset board32h04h--
Query Fan Present Status32h06h--
Obtain BBU Installation Status32h06h--
Get BBU Installation Status32h06h--
Obtains in position signal of the Pangea interface card32h06h--
Obtain Riser Card Installation Signal32h06h--
Obtains the silkscreen name32h06h--
Get Memory Fault Information Interface32h06h--
Get Board Presence Status32h06h--
Get Power Supply Presence Info32h06h--
Search for Device Alarm Information32h07h--
Obtain BBU Fru Type32h09h--
Obtain Pangea interface card type32h09h--
Obtain Riser Card Type32h09h--
Get Power Supply FRU Type32h09h--
Query Pangea Interface Card PCB Version32h0Ah--
Query Fan Board PCB Version32h0Ah--
Get BBU Hardware Version32h0Ah--
Get Backplane PCB Version Number32h0Ah--
Command for Querying the Software Version32h0Bh--
Obtain the sensor threshold32h10h--
Obtaining the BBU Electronic Label32h12h--
Obtaining the Electronic Label of the Mainboard32h12h--
Get Power Supply Electronic Label32h12h--
Query License Data32h14h--
Set License Data32h15h--
Query Backplane EEPROM Data32h16h--
Get BBU Battery Pack Product Name32h16h--
Get BBU Battery Pack Manufacturer Name32h16h--
Get BBU Battery Pack Serial Number32h16h--
Get BBU Battery Pack Manufacturing Date32h16h--
Set Backplane EEPROM data32h17h--
Set Node Master Slave Mode32h1Ch--
Obtains the active standby status of a node32h1Dh--
Query Pangea Interface Card Slot ID32h21h--
Query Fan Board Slot Number32h21h--
Query fan speed32h23h--
Query Fan Speed Level32h25h--
Set Fan Speed Level32h26h--
Query Fan Operation Mode32h27h--
Set Fan Operation Mode32h28h--
Query Fan Detailed Working Status32h29h--
Set Fan Working Status32h2Ah--
Get Power Supply Manufacturer Name32h2Bh--
Get Power Supply Name32h2Ch--
Get Power Supply Product SN32h2Dh--
Get Power Supply Production Date32h2Eh--
Get Power Supply Type32h2Fh--
Get Power Supply Huawei Code32h30h--
Get Power Supply Status32h31h--
Get Power Supply 32 bit Alarm Code32h33h--
Get Power Supply Output Power32h34h--
Get Power Supply Output Voltage32h35h--
Get Power Supply Output Current32h36h--
Set Power Supply Switch32h37h--
Get BBU temperature32h39h--
Get Power Supply Temperature32h39h--
Get BBU Cell Voltage32h3Dh--
Obtain BBU voltage32h3Eh--
Get BBU Last Discharge Time32h40h--
Get BBU 32 bit Alarm Code32h41h--
Get BBU Life Expiration Alarm32h45h--
Get BBU Life Pre expiration Time Alarm Threshold32h45h--
Get BBU Life Pre expiration Warning Alert32h45h--
Obtain BBU Running Time32h45h--
Get BBU Charging Current32h47h--
Get BBU Remaining Capacity32h47h--
Get BBU Remaining Battery Percentage32h47h--
Get BBU Working Status32h47h--
Get BBU Discharging Current32h47h--
Get BBU Full Charging Flag32h47h--
Obtain BBU status32h47h--
Get BBU Battery Pack Discharge Times32h47h--
Send power off command32h4Bh--
Set Device Indicator Status32h4Ch--
Set Fan Board Alarm Lamp Status32h4Ch--
Get Power Supply Running Status32h4Dh--
Get Power Supply Alarm Status32h4Eh--
Query component upgrade status32h51h--
Disable the watchdog32h56h--
Query Fan Name32h60h--
Obtain BBU Fru name32h60h--
Get Pangea Interface Card Name32h60h--
Get board name32h60h--
Get Power Supply FRU Name32h60h--
Obtain sensor name32h64h--
Query the Subrack Number Displayed on the Nixie Tube32h68h--
Set the Nixie Tube to Display the Frame Number32h69h--
Set equipment test mode32h6Bh--
Get Power Supply Rated Power32h70h--
Set the RAM information of a CPLD32h71h--
Set Controller BMC Reset Main System32h71h--
Set the Nixie Tube Display Mode32h71h--
Query the Nixie Tube Number System Display32h72h--
Query Valid Attribution Info of Management Port IP Configuration32h72h--
Reads the RAM information of the CPLD32h72h--
Query Retimer Upgrade Support32h73h--
Query If Light Board Supports Upgrade32h73h--
Query Pangea Interface Card VRD Remaining Upgrade Count32h74h--
To query the remaining service life of a VRD32h74h--
Query Pangea Interface Card Locator Status32h7Ah--
Query Device Indicator Status32h7Ah--
Query Fan Board Alarm Lamp Status32h7Ah--
Query Fan Identify Lamp Status32h7Ah--
Set Fan Board Lamp Status32h7Ah--
Obtains the name of each CPLD chip32h7Eh--
Set the IP Address of the Management Network Port32h85h--
Query the IP Address Configuration of the Management Network Port32h86h--
Set Port Enable Status32h88h--
Sync Management Port IP Configuration Info32h89h--
Query link status of a switch chip port32h8Ah--
Query port rate of a switching chip32h8Bh--
Query BayConfig Data32h91h--
Get BayConfig Data Length32h91h--
Clear BayConfig Data32h94h--
Set BayConfig data32h94h--
Simulate Power Supply Alarm32h97h--
Set watchdog reset time32h99h--
Get Board Reset Reason32h9Ah--
Query Pangea Interface Card Alarm Status32h9Fh--
Query Fan Board Alarm Status32h9Fh--
Obtain BBU Alarm Status32h9Fh--
Query the fan silkscreen32hA1h--
Get BBU Silkscreen32hA1h--
Get Pangea Interface Card Silk Screen Information32hA1h--
Obtain Riser Card Silkscreen32hA1h--
Get Power Supply Silk Screen32hA1h--
Query Backplane Type32hA2h--
Get Power Supply Input Power32hA3h--
Obtain the sensor aggregation type32hB0h--
Obtain the sensor alarm status32hB1h--
Obtain the sensor reading value32hB2h--
Query FRU Alarm Aggregation32hB3h--
Query Light Board Locator Status32hB4h--
Query Light Board Actual Locator Status32hB4h--
Query Light Board Expected Locator Status32hB4h--
Query Fan Speed Gear Levels32hB4h--
Obtain BBU Online Test Switch32hB4h--
Get BBU Hardware and Software Version32hB4h--
Get BMC Basic Information32hB4h--
Obtains the NUMA flag32hB4h--
Set BBU Online Test Switch32hB5h--
Sets the NUMA flag to the default value32hB5h--
Sets the NUMA flag32hB5h--
Set Light Board Locator Status32hB5h--
Query Fan Board Alarm Count32hB9h--
Get Riser Card Alarm Count32hB9h--
Get Power Supply Alarm Count32hB9h--
Obtain the Number of Device Alarms32hB9h--
Get Sensor Alarm Count32hBAh--
Query ARB split brain32hBBh--
Query CCDB Data32hBBh--
Make Main System Synchronize Key Files To BMC32hBBh--
Query BBU Repair Flag32hBBh--
Query CPU Fault Core Info32hBBh--
Query CPU Core Fault Flag32hBBh--
Query GESWITCH Port Transmit and Receive Packet Statistics32hBBh--
Query OS Startup Status32hBBh--
Query OS Reset Type32hBBh--
Query PCIe P2P Function Switch32hBBh--
Query Pangea Interface Card DDR Type32hBBh--
Query Pangea Interface Card EEPROM Data32hBBh--
Query Pangea Interface Card VRD Type32hBBh--
Query Pangea Interface Card VRD Upgrade Support32hBBh--
Query Pangea Interface Card Access Restriction Flag32hBBh--
Query Riser Card Electronic Label32hBBh--
Query Switch Chip VlanId32hBBh--
Get In band Management Software Type32hBBh--
Query Extension Board Type32hBBh--
Query Controller FRU Type32hBBh--
Query Smartcooling Mode32hBBh--
Query Onboard Optical Module Info32hBBh--
Query Onboard Optical Module Presence Info32hBBh--
Query Enclosure Button Management Mode32hBBh--
Query Frame Normal And Abnormal Power off Flag32hBBh--
Query Light Board Serial Loopback Test Result32hBBh--
Query Light Board Type32hBBh--
Query System Power Supply Mode32hBBh--
Query Backplane EEPROM Product Data Update Result32hBBh--
Query Backplane EEPROM Product Data32hBBh--
Query Remote Power On Networking Mode32hBBh--
Query Fan Minimum Speed Level32hBBh--
Query Fan Electronic Label32hBBh--
Obtain BBU 0502 code32hBBh--
Get BBU ready status32hBBh--
Get BBU Online Test Status32hBBh--
Obtains the basic BMC type32hBBh--
Obtains the flag for automatically starting the CCDB and transferring data to the memory32hBBh--
Get CPU Onboard Speed32hBBh--
Get EMMC IO Statistical Error Count32hBBh--
Get Pangea Interface Card MCU Reset Flag32hBBh--
Obtain QoS information about a Pangea interface card32hBBh--
Get Pangea Interface Card Quantity32hBBh--
Obtain the service period of the electronic insurance policy of the Pangea interface card32hBBh--
Obtain the start time of the electronic insurance policy of the Pangea interface card32hBBh--
Get Card E label32hBBh--
Get Pangea Interface Card Electronic Label32hBBh--
Get Pangea Interface Card Capability Information32hBBh--
Obtain self description of a Pangea interface card32hBBh--
Obtain memory fault information32hBBh--
Get Single Power Supply Working Mode32hBBh--
Get Board OS Boot Status32hBBh--
Obtain Startup Status of a Board32hBBh--
Get National Cryptography Head Model32hBBh--
Get Local Controller CPLD and Memory UCE Alarm Status32hBBh--
Get Power Supply 12V Voltage Status32hBBh--
Get Power Supply LoadInfo Type Info32hBBh--
Get Power Supply Master Slave Mode Support32hBBh--
Obtain electronic label content of the Pangea card32hBBh--
Get Backplane EEPROM Write Count32hBBh--
Read the service period of the electronic insurance policy32hBBh--
Read the start time of the electronic insurance policy32hBBh--
ARB split brain registration32hBCh--
ARB split brain deregistration32hBCh--
CCDB data registration32hBCh--
Cold Reset OS32hBCh--
Switch Pangea Interface Card EEPROM IIC Channel32hBCh--
Synchronize storage users to the BMC32hBCh--
Reset Interface Card MCU32hBCh--
Restore the Default BMC User32hBCh--
Run the cpld refresh command32hBCh--
Controller Force Power On32hBCh--
Update Backplane EEPROM Product Data32hBCh--
Query Persistent Stored CPLD RAM Flag32hBCh--
Query High Temperature Recovery Auto Power on Scene Flag32hBCh--
Simulate Interface Card Removal32hBCh--
Clear Pangea Interface Card MCU Reset Flag32hBCh--
Clear High Temperature Recovery Auto Power on Scene Flag32hBCh--
Unlock BBU fault32hBCh--
Set BBU run signal32hBCh--
Set BBU Charging High and Low Current32hBCh--
Set BBU Online Test Redundant Node Health Status32hBCh--
Set BBU Switch Status32hBCh--
Set BIOS Memory Self test Flag32hBCh--
Sets the flag for automatically starting the CCDB and transferring data to the memory32hBCh--
Set CPLD RAM Flag With Persistent Storage32hBCh--
Set CPU Fault Core Info32hBCh--
Set CPU onboard rate32hBCh--
Set CPU Core Fault Flag32hBCh--
Set Carrier CPLD Master Slave Switch32hBCh--
Set PCIe P2P function switch32hBCh--
Set Pangea Interface Card EEPROM Data32hBCh--
Set QoS Information for a Pangea Interface Card32hBCh--
Set the start time of the electronic insurance policy for the Pangea interface card32hBCh--
Set the service period of the electronic insurance policy for the Pangea interface card32hBCh--
Set Pangea Interface Card Type32hBCh--
Sets self description of a Pangea interface card32hBCh--
Set Pangea Interface Card Access Restriction Flag32hBCh--
Set Switch Chip Port VlanId32hBCh--
Set Memory Refresh Frequency Mode32hBCh--
Set National Cryptography Head Model32hBCh--
Set Storage Node Auto Power on Flag After Abnormal Shutdown32hBCh--
Set In band Management Software Type32hBCh--
Set Extension Board Type32hBCh--
Enable or disable password less users(machine machine users)32hBCh--
Set Smartcooling Mode32hBCh--
Set Onboard Optical Module Optical Signal Transmit Switch32hBCh--
Set Frame Normal And Abnormal Power off Flag32hBCh--
Set Light Board Serial Loopback Test32hBCh--
Set the service period of the digital warranty32hBCh--
Set the start time of the electronic insurance policy32hBCh--
Set Power Supply Switch Status32hBCh--
Set the electronic label content of the Pangea card32hBCh--
Set System Power Supply Mode32hBCh--
Set Backplane EEPROM Product Data32hBCh--
Set Remote Power On Networking Mode32hBCh--
Set Fan Minimum Speed Level32hBCh--
Notify Cluster Power On32hBCh--
Query All Hard Disk LED Status32hD0h--
Obtain Power Status of a Hard Disk32hD0h--
Set Power Status of a Hard Disk32hD1h--
To query whether a component supports the upgrade command32hD4h--
Deregister the imu key32hD5h--
Querying the Key Setting Status32hD6h--
Setting the IMU Key File32hD7h--
Issue the link scanning command32hD9h--
Query link status of a component32hDAh--
Set Controller Power On And Off Process Status32hE0h--
Query Fan Health Status32hE9h--
Accept Peer Controller Power On Command Request32hEBh--
Query Controller Handshake Info32hF4h--
Query Fan Working Status32hF6h--
Set ARB Split Brain Update Interrupt32hF9h--
Set Bracket Temperature Information Synchronization32hF9h--
Set Frame Information Synchronization32hF9h--
Query Controller Heartbeat Info32hFCh--

定制类命令(NetFn:3Eh)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Get OEM Support Status3Eh02h--
Get Device Health Status3Eh03h--
Get Version Info3Eh07h--
Get Fan information3Eh10h--
Get Sensor Value3Eh31h--
Restore to Manufacture setting3Eh3Fh--
Get Device Information3Eh40h--
Set Security Status3Eh5Ah--
Get Security Status3Eh5Bh--
Capture Screen3Eh60h--

定制类命令(NetFn:3Ah)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
Chassis Dpu Power Off3AhF5h--
Set Force Power On Status3AhF6h--
Get BMC SOL Source3AhF7h--
Set BMC SOL Source3AhF7h--

SMM专用类命令(NetFn:0Ch,Cmd:F1h,限制使用)

命令描述网络功能码(NetFn)命令字(Cmd)子命令字(SubCmd)
SMM Start Up Notification0ChF1h--

其他命令