Set Sensor Threshold 命令详情
更新时间:2025/06/26
在Gitcode上查看源码

修订记录

openUBMC版本号修订日期修订人修订内容
25.062025/06/26pengqiang-gs初稿,新增命令详情

基本信息

功能说明

设置具体传感器的门限值。 This command is used to set the specified threshold for the given sensor.

权限

ReadOnly

命令信息

请求信息

字节顺序域取值说明
1sensor number (FFh = reserved)
2[7:6] - reserved. Write as 00b.
[5] - 1b = set upper non-recoverable threshold
[4] - 1b = set upper critical threshold
[3] - 1b = set upper non-critical threshold
[2] - 1b = set lower non-recoverable threshold
[1] - 1b = set lower critical threshold
[0] - 1b = set lower non-critical threshold
3lower non-critical threshold.
Ignored if bit 0 of byte 2 = 0
4lower critical threshold.
Ignored if bit 1 of byte 2 = 0
5lower non-recoverable threshold.
Ignored if bit 2 of byte 2 = 0
6upper non-critical threshold.
Ignored if bit 3 of byte 2 = 0
7upper critical threshold value.
Ignored if bit 4 of byte 2 = 0
8upper non-recoverable threshold value.
Ignored if bit 5 of byte 2 = 0

响应信息

字节顺序域取值说明
1Completion Code.

命令样例

样例1:

  • 请求:
  • 响应:

返回到索引