Set Sensor Hysteresis 命令详情
更新时间:2025/06/26
在Gitcode上查看源码修订记录
| openUBMC版本号 | 修订日期 | 修订人 | 修订内容 |
|---|---|---|---|
| 25.06 | 2025/06/26 | pengqiang-gs | 初稿,新增命令详情 |
基本信息
功能说明
设置具体传感器门限关联的迟滞量。 This command provides a mechanism for setting the hysteresis values associated with the thresholds of a sensor that has threshold based event generation.
权限
ReadOnly
命令信息
请求信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | sensor number (FFh = reserved) |
| 2 | reserved for future ‘hysteresis mask’ definition. Write as ‘FFh’ |
| 3 | Positive-going Threshold Hysteresis Value. Set to 00h if sensor does not support positive-going threshold hysteresis. This value is subtracted from positive going thresholds to determine the point where the asserted status for that threshold will clear. |
| 4 | Negative-going Threshold Hysteresis Value. This value is added to negative going thresholds to determine the point where the asserted status for that threshold will clear. Set to 00h if sensor does not support negative-going threshold hysteresis. |
响应信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | Completion Code. |
命令样例
样例1:
- 请求:
- 响应: