Set Sensor Hysteresis
更新时间: 2025/06/26
在Gitcode上查看源码

24h-设定传感器迟滞(Set-Sensor-Hysteresis)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设定传感器迟滞。

权限

BasicSetting

命令信息

请求信息

字节顺序域取值说明
NetFnS/E 04h
CMD24h
1sensor number (FFh=reserved)
2reserved for future 'hysteresis mask' definition. Write as 'FFh'
3Positive-going Threshold Hysteresis Value. Set to 00h if sensor does not
support positive-going threshold hysteresis. This value is subtracted from
positive going thresholds to determine the point where the asserted status for that threshold will clear.
4Negative-going Threshold Hysteresis Value. This value is added to negative
going thresholds to determine the point where the asserted status for that
threshold will clear. Set to 00h if sensor does not support negative-going
threshold hysteresis.

响应信息

字节顺序域取值说明
1Completion Code

命令样例

设定传感器迟滞

请求:

ipmicmd -k "0f 00 04 24 01 ff 03 03" smi 0

响应:

0f

返回到索引