Set Fan Level
更新时间: 2025/06/26
在Gitcode上查看源码

15h-设置风扇等级(Set-Fan-Level)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设置风扇等级。

权限

BasicSetting

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD15h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.
2FRU Device ID. Indicates an individual FRU device to query.
3Fan Level. To be accepted, this value is:- greater than or equal to Minimum Speed Level and less than or equal to Maximum Speed Level.- FEh (Shut Down)- FFh (Local Control).
(4)Local Control Enable State[1]. This field is optional. Set this to 0 to disable, or 1 to enable, Local Control mode.

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.

命令样例

设置风扇等级

请求:

ipmicmd -k "0f 00 MM NN" smi 0

响应:

0f MM NN

返回到索引