Set Power Level
更新时间: 2025/06/26
在Gitcode上查看源码

11h-设定功率等级(Set-Power-Level)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设定功率等级。

权限

PowerMgnt

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD11h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.
2FRU Device ID. Indicates an individual FRU device to query.
3Power Level
00=Power off, only the mandatory support circuitry is running (e.g. IPM Controller, fans running to cool management circuitry, PEMs, FRU devices).
01h-14h=Select the power level, if available.
FFh=Do not change current power level.
All other values reserved.
4Set Present Levels to Desired Levels
00h=Do not change present levels
01h=Copy desired levels to present levels.
All other values reserved.

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used

命令样例

设定功率等级

请求:

ipmicmd -k "0f 00 2c 12 00 00 01" smi 0

响应:

0f 2d 00 12 00 00 01 1e 1e b8 b8

返回到索引