Compute Power Properties
更新时间: 2025/06/26
在Gitcode上查看源码

10h-计算功率属性(Compute-Power-Properties)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

计算功率属性。

权限

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD10h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used
2FRU Device ID. Indicates an individual FRU device to lock in the power properties

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used
3Number of Spanned Slots. Indicates the total number of Slots spanned by the Board. This is 1 for a Board that inserts into a single Slot and any non-Board FRU
4IPM Controller Location. When a Board spans more than one Slot (a multi-Slot Board), the Shelf Manager needs to know which Slot contains the IPM Controller. This number treats the left most Slot location of the multi-Slot Board as 0 and increment by single units moving to the right.
This value is 0 for a Board that inserts into a single Slot and any non- Board FRU. This value represents the location of the Zone 1 connection for the Board

命令样例

计算功率属性

请求:

ipmicmd -k "0f 00 MM NN" smi 0

响应:

0f MM NN

返回到索引