Get FRU Activation Policy
更新时间: 2025/06/26
在Gitcode上查看源码

0Bh-获取FRU激活策略(Get-FRU-Activation-Policy)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

获取FRU激活策略。

权限

ReadOnly

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD0Bh
1PICMG Identifier, Indicates that this is a PICMG-defined group.
extension command, A value of 00h is used.
2FRU Device ID
1 Field changed in Engineering Change Notice 3.0-1.0-001 of this specification.

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier, Indicates that this is a PICMG-defined group extension command.
A value of 00h is used.
3FRU Activation Policy[1]
[7:2]=Reserved. Write as 0000 00b
[1]=Deactivation-Locked bit. A 1b indicates the FRU is Deactivation-Locked. If it is in the M4 state, it will not transition to M5 until this bit is cleared.
[0]=Locked bit. A 1b indicates the FRU is locked and if it is in the M1 state, it will not transition on to M2 until unlocked.

命令样例

获取FRU激活策略

[root@localhost ~]# ipmicmd -k "0f 00 2c 0b 00 00" smi 0

0f 2d 00 0b 00 00 02

返回到索引