Set FRU Activation Policy
更新时间: 2025/06/26
在Gitcode上查看源码

0Ah-设置FRU激活策略(Set-FRU-Activation-Policy)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设置FRU激活策略。

权限

PowerMgnt

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD0Ah
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.
2FRU Device ID
3FRU Activation Policy Mask Bits[1]
[7:2]=Reserved. Write as 0000 00b
[1]=1–Bit in Byte 4 of command will affect the Deactivation-Locked bit
[0]=1–Bit in Byte 4 of command will affect the Locked bit
4FRU Activation Policy Set Bits[1]
[7:2]=Reserved. Write as 0000 00b
[1]=(ignored if Bit 1 of Byte 3=0)
0b-Clear Deactivation-Locked–FRU can transition from M4 to M5
1b-Set Deactivation-Locked–FRU cannot transition from M4 to M5
[0]=(ignored if Bit 0 of Byte 3=0)
0b-Clear Locked–FRU can transition from M1 to M2
1b-Set Locked–FRU cannot transition from M1 to M2
1 Field changed in Engineering Change Notice 3.0-1.0-001 of this specification.

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.

命令样例

设置FRU激活策略

请求:

ipmicmd -k "0f 00 2c 0a 00 01 00 00" smi 0

响应:

0f 2d 00 0a 00 00