Set IPMB State
更新时间: 2025/06/26
在Gitcode上查看源码

09h-设置IPMB状态(Set-IPMB-State)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设置IPMB状态。

权限

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD09h
1PICMG Identifier, Indicates that this is a PICMG-defined group extension command
A value of 00h is used
2IPMB-A State[1], Indicates the state of IPMB-A.
Options are:
[0]-IPMB-A State
0h=Override state-Isolate (disable)
1h=Local Control state-IPM Controller determines state of IPMB-A
[1:7]-IPMB-0 Link Identification
00h=Select All IPMB-0 Links (also the value for bused IPMB-0)
01h-5Fh=IPMB-0 Link Number 1 to 95
60h-7Eh=reserved
If Byte 2=FFh, command does not change current state of IPMB-A
3IPMB-B State[1], Indicates the state of IPMB-B
Options are:
[0]-IPMB-B State
0h=Override state-Isolate (disable)
1h=Local Control state-IPM Controller determines state of IPMB-B
[1:7]-IPMB-0 Link Identification
00h=Select All IPMB-0 Links (also the value for bused IPMB-0)
01h-5Fh=IPMB-0 Link Number 1 to 95
60h-7Eh=reserved
If Byte 3=FFh, command does not change current state of IPMB-B
1 Field changed in Engineering Change Notice 3.0-1.0-001 of this specification

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command.
A value of 00h is used

命令样例

设置IPMB状态

请求:

ipmicmd -k "0f 00 MM NN" smi 0

响应:

0f MM NN

返回到索引