Get FRU LED Properties
更新时间: 2025/06/26
在Gitcode上查看源码

05h-获取FRU-LED属性(Get-FRU-LED-Properties)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

获取FRU LED属性。

权限

ReadOnly

命令信息

请求信息

字节顺序域取值说明
NetFnPICMG 2Ch
CMD05h
1PICMG Identifier, Indicates that this is a PICMG defined group extension command. A value of 00h is used
2FRU Device ID

响应信息

字节顺序域取值说明
1Completion Code
2PICMG Identifier
Indicates that this is a PICMG defined group extension command. A value of 00h is used
3General Status LED Properties
A bit field indicating the FRU's ability to control the four LEDs . When a bit is set, the FRU can control the associated LED
Bit LED Name
[7:4] Reserved, is set to 0.
[3] LED
[2] LED 2
[1] LED 1
[0] BLUE LED
4Application Specific LED Count
The number of application specific LEDs under control of the IPM Controller
00h-FBh Number of application specific LEDs under control by IPM Controller. If no application specific LEDs are present this field is 00h
FCh-FFh Reserved

命令样例

获取FRU LED属性

请求:

ipmicmd -k "0f 00 2c 05 00 00" smi 0

响应:

0f 2d 00 05 00 00 04 01

返回到索引