Set Power Restore Policy
更新时间: 2025/06/26
在Gitcode上查看源码

06h-设置BMC的通电开机策略(Set-Power-Restore-Policy)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设置BMC的通电开机策略。

权限

PowerMgnt

命令信息

请求信息

字节顺序域取值说明
NetFnChassis 00h
CMD06h
1[7:3]-reserved
[2:0]-power restore policy
011b=no change (just get present policy support)
010b=chassis always powers up after AC/mains is applied or returns.
001b=after AC/mains is applied or returns, power is restored to the state that was in effect when AC/mains was removed or lost.
000b=chassis always stays powered off after AC/mains is applied, power pushbutton or command required to power on system.
all other=reserved

响应信息

字节顺序域取值说明
1Completion Code. A non-zero completion code should be returned if an attempt is made to set a policy option that is not supported
2power restore policy support (bitfield)
[7:3]-reserved
[2]-1b=chassis supports always powering up after AC/mains returns.
[1]-1b=chassis supports restoring power to state that was in effect when AC/mains was lost
[0]-1b=chassis supports staying powered off after AC/mains returns

命令样例

请求:

ipmicmd -k "0f 00 00 06 03" smi 0

响应:

0f 01 00 06 00 04