Set Chassis Capabilities
更新时间: 2025/06/26
在Gitcode上查看源码

05h-设置机箱能力(Set-Chassis-Capabilities)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

设置机箱功能。

权限

命令信息

请求信息

字节顺序域取值说明
NetFnChassis 00h
CMD05h
1


Capabilities Flags
[7:2]- reserved
[1]- 1b=Provides Front Panel Lockout.
[0]- 1b=Provides intrusion
2Chassis FRU Info Device Address (see Get Chassis Capabilities for a description of these addresses, their use, and the field formatting.)
3Chassis SDR Device Address
4Chassis SEL Device Address
5Chassis SM Device Address
(6)Chassis Bridge Device Address

响应信息

字节顺序域取值说明
1Completion Code. Note, this command does not return an error completion code if an attempt is made to change a 'read-only' parameter
Software must check which fields in the response match the value from the request by using the Get Chassis Capabilities command

命令样例

设置机箱功能

请求:

ipmicmd -k "0f 00 MM NN" smi 0

响应:

0f MM NN

返回到索引