Set Chassis Capabilities
更新时间: 2025/06/26
在Gitcode上查看源码05h-设置机箱能力(Set-Chassis-Capabilities)
修订记录
| openUBMC版本号 | 修订日期 | 修订内容 |
|---|---|---|
| 25.06 | 2025/06/26 | 初稿,新增命令详情 |
基本信息
功能说明
设置机箱功能。
权限
命令信息
请求信息
| 字节顺序 | 域取值说明 |
|---|---|
| NetFn | Chassis 00h |
| CMD | 05h |
| 1 | Capabilities Flags [7:2]- reserved [1]- 1b=Provides Front Panel Lockout. [0]- 1b=Provides intrusion |
| 2 | Chassis FRU Info Device Address (see Get Chassis Capabilities for a description of these addresses, their use, and the field formatting.) |
| 3 | Chassis SDR Device Address |
| 4 | Chassis SEL Device Address |
| 5 | Chassis SM Device Address |
| (6) | Chassis Bridge Device Address |
响应信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | Completion Code. Note, this command does not return an error completion code if an attempt is made to change a 'read-only' parameter Software must check which fields in the response match the value from the request by using the Get Chassis Capabilities command |
命令样例
设置机箱功能
请求:
ipmicmd -k "0f 00 MM NN" smi 0响应:
0f MM NN