Get Chassis Capabilities 命令详情
更新时间:2025/06/26
在Gitcode上查看源码

修订记录

openUBMC版本号修订日期修订人修订内容
25.062025/06/26pengqiang-gs初稿,新增命令详情

基本信息

功能说明

查询机框管理的能力集合。 This command returns information about which main chassis management functions are present on the IPMB (or virtual IPMB) and what addresses are used to access those functions.

权限

BasicSetting

命令信息

请求信息

无请求信息

响应信息

字节顺序域取值说明
1Completion Code
2Capabilities Flags
[7:4] - reserved
[3] - 1b = provides power interlock (IPMI 1.5)
[2] - 1b = provides Diagnostic Interrupt (FP NMI) (IPMI 1.5)
[1] - 1b = Provides “Front Panel Lockout” (this indicates that the chassis has capabilities to lock out external power control and reset button or front panel interfaces and/or detect tampering with those interfaces)
[0] - 1b = Chassis provides intrusion (physical security) sensor
3Chassis FRU Info Device Address.

Note: all IPMB addresses used in this command are have the 7-bit I2C slave address as the most-significant 7-bits and the least significant bit set to 0b.
 00h = unspecified.
4Chassis SDR Device Address
5Chassis SEL Device Address
6Chassis System Management Device Address
(7)Chassis Bridge Device Address. Reports location of the ICMB bridge function. If this field is not provided, the address is assumed to be the BMC address (20h). Implementing this field is required when the Get Chassis Capabilities command is implemented by a BMC, and whenever the Chassis Bridge function is implemented at an address other than 20h.

命令样例

样例1:

  • 请求:ipmitool raw 0x00 0x00
  • 响应:00