Get Chassis Capabilities
更新时间: 2025/06/26
在Gitcode上查看源码

00h-获取机框能力(Get-Chassis-Capabilities)

修订记录

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息

功能说明

获取机箱功能。

权限

ReadOnly

命令信息

请求信息

参数(字节)域取值说明
NetFnChassis 00h
CMD00h

响应信息

字节顺序域取值说明
1Completion Code
2Capabilities Flags
[7:4]-reserved
[3]-1b=provides power interlock (IPMI 1.5)
[2]-1b=provides Diagnostic Interrupt (FP NMI) (IPMI 1.5)
[1]-1b=Provides “Front Panel Lockout” (this indicates that the chassis has capabilities to lock out external power control and reset button or front panel interfaces and/or detect tampering with those interfaces.)
[0]-1b=Chassis provides intrusion (physical security) sensor
3Chassis FRU Info Device Address.
Note: all IPMB addresses used in this command are have the 7-bit I2C slave address as the most-significant 7-bits and the least significant bit set to 0b
00h=unspecified
4Chassis SDR Device Address
5Chassis SEL Device Address
6Chassis System Management Device Address
(7)Chassis Bridge Device Address. Reports location of the ICMB bridge function. If this field is not provided, the address is assumed to be the BMC address (20h). Implementing this field is required when the Get Chassis Capabilities command is implemented by a BMC, and whenever the Chassis
Bridge function is implemented at an address other than 20h

命令样例

获取机箱功能

请求:

ipmicmd -k "0f 00 00 00" smi 0

响应:

0f 01 00 00 00 00 20 20 20 20 20