Get Chassis Capabilities
更新时间: 2025/06/26
在Gitcode上查看源码00h-获取机框能力(Get-Chassis-Capabilities)
修订记录
| openUBMC版本号 | 修订日期 | 修订内容 |
|---|---|---|
| 25.06 | 2025/06/26 | 初稿,新增命令详情 |
基本信息
功能说明
获取机箱功能。
权限
ReadOnly
命令信息
请求信息
| 参数(字节) | 域取值说明 |
|---|---|
| NetFn | Chassis 00h |
| CMD | 00h |
响应信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | Completion Code |
| 2 | Capabilities Flags [7:4]-reserved [3]-1b=provides power interlock (IPMI 1.5) [2]-1b=provides Diagnostic Interrupt (FP NMI) (IPMI 1.5) [1]-1b=Provides “Front Panel Lockout” (this indicates that the chassis has capabilities to lock out external power control and reset button or front panel interfaces and/or detect tampering with those interfaces.) [0]-1b=Chassis provides intrusion (physical security) sensor |
| 3 | Chassis FRU Info Device Address. Note: all IPMB addresses used in this command are have the 7-bit I2C slave address as the most-significant 7-bits and the least significant bit set to 0b 00h=unspecified |
| 4 | Chassis SDR Device Address |
| 5 | Chassis SEL Device Address |
| 6 | Chassis System Management Device Address |
| (7) | Chassis Bridge Device Address. Reports location of the ICMB bridge function. If this field is not provided, the address is assumed to be the BMC address (20h). Implementing this field is required when the Get Chassis Capabilities command is implemented by a BMC, and whenever the Chassis Bridge function is implemented at an address other than 20h |
命令样例
获取机箱功能
请求:
ipmicmd -k "0f 00 00 00" smi 0响应:
0f 01 00 00 00 00 20 20 20 20 20