Reset Watchdog Timer
更新时间: 2025/06/26
在Gitcode上查看源码22h-复位BMC看门狗计时器(Reset-Watchdog-Timer)
修订记录
| openUBMC版本号 | 修订日期 | 修订内容 |
|---|---|---|
| 25.06 | 2025/06/26 | 初稿,新增命令详情 |
基本信息
功能说明
复位BMC看门狗计时器。
权限
PowerMgnt
命令信息
请求信息
| 字节顺序 | 域取值说明 |
|---|---|
| NetFn | App 06h |
| CMD | 22h |
| - | 无 |
响应信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | Completion Code. Generic plus the following command-specific completion codes: 80h=Attempt to start un-initialized watchdog. It is recommended that a BMC implementation return this error completion code to indicate to software that a Set Watchdog Timer command has not been issued to initialize the timer since the last system power on, reset, or BMC reset. Note that since many systems may initialize the watchdog timer during BIOS operation, this condition may only be seen by software if a BMC gets re-initialized during system operation (as might be the case if a firmware update occurred, for example). |
命令样例
复位BMC看门狗计时器
请求:
ipmicmd -k "0f 00 06 22" smi 0响应:
0f 07 00 22 80