代码仓
中
DeviceInfo
更新时间: 2026/10/29
在AtomGit上查看源码

ResourceDefinition ​

uris ​

  • /redfish/v1/Managers/manager_id/SPService/DeviceInfo

properties ​

名称类型是否只读取值范围/枚举值说明
@odata.contextstringtrue-SP服务的硬件信息资源模型的OData描述信息
@odata.idstringtrue-SP服务的硬件信息资源的访问路径
@odata.typestringtrue-SP服务的硬件信息资源的类型
Idstringtrue-SP服务的硬件信息资源的Id
Namestringtrue-SP服务的硬件信息资源的名称
PCIeCards [ {arraytrue-PCIe卡信息列表
PCIeCards[].DeviceNamestringfalse-丝印
PCIeCards[].Controlers[ ]arraytrue-PCIe卡的控制器列表
PCIeCards[].Controlers[].Modelstringfalse-型号
PCIeCards[].Controlers[].Functions[ ]arraytrue-控制器的功能列表
PCIeCards[].Controlers[].Functions[].VendorIdstringfalse-厂商id
PCIeCards[].Controlers[].Functions[].BDFNumber {objecttrue-BDF编号
PCIeCards[].Controlers[].Functions[].BDFNumber.BDFstringfalse-BDF
PCIeCards[].Controlers[].Functions[].BDFNumber.RootBDFstringfalse-根BDF
}
PCIeCards[].Controlers[].Functions[].Descriptionstringtrue-描述信息
PCIeCards[].Controlers[].Functions[].MacAddressstringfalse-MAC地址
PCIeCards[].Controlers[].Functions[].DeviceIdstringfalse-设备ID
PCIeCards[].Controlers[].Functions[].SubsystemIdstringfalse-子系统ID
PCIeCards[].Controlers[].Functions[].CardTypestringfalse-卡类型
PCIeCards[].Controlers[].Functions[].SubsystemVendorIdstringfalse-子系统厂商ID
} ]
PCIeCards[].Controlers[].FirmwareVersionstringfalse-固件版本
PCIeCards[].Controlers[].Manufacturerstringfalse-厂商信息
} ]
PCIeCards[].DeviceLocatorstringfalse-丝印信息
PCIeCards[].Positionstringfalse-位置信息
} ]

supported_methods ​

  • GET

HTTP methods ​

GET ​

命令功能

查询 SP 服务的硬件信息资源

命令格式

URL: https://device_ip/redfish/v1/Managers/manager_id/SPService/DeviceInfo

请求头:

text
X-Auth-Token: auth_value

请求消息体: 无

参数说明

参数参数说明取值
device_ip登录设备的IP地址IPv4或IPv6地址
auth_value请求消息的鉴权参数可通过/redfish/v1/SessionService/Sessions创建会话时获得

使用指南

响应结果以最新SP版本的实际返回结果为准。 GA140C机型不支持 SP版本和机型兼容性列表详见Smart Provisioning用户指南

使用实例

请求样例: GET https://device_ip/redfish/v1/Managers/manager_id/SPService/DeviceInfo

X-Auth-Token: auth_value 请求消息体:无

响应样例:

json
{
"@odata.context": "/redfish/v1/$metadata#HwDeviceInfo.HwDeviceInfo",
"@odata.id": "/redfish/v1/Managers/1/SPService/DeviceInfo",
"@odata.type": "#HwDeviceInfo.v1_0_0.HwDeviceInfo",
"Id": "DeviceInfo",
"Name": "Device Info",
"PCIeCards": [
{
"DeviceName": "LOM",
"Controlers": [
{
"Model": null,
"Functions": [
{
"VendorId": "0x8086",
"BDFNumber": {
"BDF": "0000:1a:00.0",
"RootBDF": "0000:19:03.0"
},
"Description": "Intel Corporation Device 37d2 (rev 08)",
"MacAddress": null,
"DeviceId": "0x37d2",
"SubsystemId": "0xd122",
"CardType": "NIC",
"SubsystemVendorId": "0x19e5"
},
{
"VendorId": "0x8086",
"BDFNumber": {
"BDF": "0000:1a:00.1",
"RootBDF": "0000:19:03.0"
},
"Description": "Intel Corporation Device 37d2 (rev 08)",
"MacAddress": null,
"DeviceId": "0x37d2",
"SubsystemId": "0xd122",
"CardType": "NIC",
"SubsystemVendorId": "0x19e5"
},
{
"VendorId": "0x8086",
"BDFNumber": {
"BDF": "0000:1a:00.2",
"RootBDF": "0000:19:03.0"
},
"Description": "Intel Corporation Device 37d1 (rev 08)",
"MacAddress": null,
"DeviceId": "0x37d1",
"SubsystemId": "0xd122",
"CardType": "NIC",
"SubsystemVendorId": "0x19e5"
},
{
"VendorId": "0x8086",
"BDFNumber": {
"BDF": "0000:1a:00.3",
"RootBDF": "0000:19:03.0"
},
"Description": "Intel Corporation Device 37d1 (rev 08)",
"MacAddress": null,
"DeviceId": "0x37d1",
"SubsystemId": "0xd122",
"CardType": "NIC",
"SubsystemVendorId": "0x19e5"
}
],
"FirmwareVersion": "3.25 0x800009f4 255.65535.255",
"Manufacturer": "Intel Corporation"
}
],
"DeviceLocator": "mainboard",
"Position": "LOM"
},
{
"DeviceName": "SM211",
"Controlers": [
{
"Model": "i350",
"Functions": [
{
"VendorId": "0x8086",
"BDFNumber": {
"BDF": "0000:af:00.1",
"RootBDF": "0000:ae:00.0"
},
"Description": "Intel Corporation I350 Gigabit Network Connection (rev 01)",
"MacAddress": null,
"DeviceId": "0x1521",
"SubsystemId": "0xd10c",
"CardType": "NIC",
"SubsystemVendorId": "0x19e5"
},
{
"VendorId": "0x8086",
"BDFNumber": {
"BDF": "0000:af:00.0",
"RootBDF": "0000:ae:00.0"
},
"Description": "Intel Corporation I350 Gigabit Network Connection (rev 01)",
"MacAddress": null,
"DeviceId": "0x1521",
"SubsystemId": "0xd10c",
"CardType": "NIC",
"SubsystemVendorId": "0x19e5"
}
],
"FirmwareVersion": "1.63,0x800009fa",
"Manufacturer": "Intel Corporation"
}
],
"DeviceLocator": "mainboard",
"Position": "NIC1"
}
]
}

响应码:200