代码仓
中
Boards
更新时间: 2026/11/04
在AtomGit上查看源码

ResourceDefinition ​

uris ​

  • /redfish/v1/Chassis/chassis_id/Boards/board_id

properties ​

名称类型是否只读取值范围/枚举值说明
@odata.contextstringtrue-指定扩展板卡资源模型的OData描述信息
@odata.idstringtrue-指定扩展板卡资源的访问路径
@odata.typestringtrue-指定扩展板卡资源的类型
Idstringtrue-指定扩展板卡资源ID
Descriptionstringtrue-指定扩展板卡描述信息
Namestringtrue-指定扩展板卡资源名称
CardNonumbertrue-指定扩展板卡编号
Status {objecttrue-指定扩展板卡的状态包括:
● State:扩展板卡使能状态
● Health:扩展板卡健康状态
● Severity:扩展板卡的自定义健康状态
Status.Healthstringtrue-指定扩展板卡服务健康状态
Status.SeveritystringtrueInformational、Minor、Major、Critical指定扩展板卡的自定义健康状态
Status.Statestringtrue-指定扩展板卡的内存的在位状态
}
DeviceLocatorstringtrue-指定扩展板卡的丝印
DeviceTypestringtrue-指定扩展板卡的类型
Locationstringtrue-指定扩展板卡的容器
Manufacturerstringtrue-指定扩展板卡生产厂商
ProductNamestringtrue-指定扩展板卡产品名称
SerialNumberstringtrue-指定扩展板卡序列号
PartNumberstringtrue-指定扩展板卡部件号
AssetTagstringtrue-指定扩展板卡资产标签
CPLDVersionstringtrue-指定扩展板卡CPLD版本
PCBVersionstringtrue-指定扩展板卡PCB版本
BoardNamestringtrue-指定扩展板卡单板名称
BoardIdstringtrue-指定扩展板卡单板Id
ComponentUniqueIDstringtrue-指定扩展板卡的组件唯一标识
说明
openUBMC 25.12 LTS及以上版本支持
ManufactureDatestringtrue-指定扩展板卡制造日期
AssociatedResourcestringtrue-指定扩展板卡的归属资源
PositionIdstringtrue-指定扩展板卡的位号
PowerWattsstringtrue-指定扩展板卡的功率
说明:已屏蔽该属性值频繁变化导致的事件上报
LinkWidthAbilitystringtrue-指定扩展板卡的带宽规格
LinkSpeedAbilitystringtrue-指定扩展板卡的连接速率规格
LinkWidthstringtrue-指定扩展板卡的当前带宽
LinkSpeedstringtrue-指定扩展板卡的当前速率
PchModelstringtrue-当前主板PCH型号
SupportedRAIDLevelsstringtrue-Raid卡支持的raid级别
FirmwareVersionstringtrue-指定扩展板卡的固件版本
说明:目前只有200 IOB卡支持
WorkModestringfalse-指定拓展板卡的工作模式,取值如下:
● AMP:独立模式
● SMP:集成模式
说明:目前只有A800-9000,A800-9010及A300-9000的NPU卡支持
M2Device1Presencebooleantrue-CIC卡的M.2卡槽位1在位情况
说明:目前只有S920X05的CIC卡支持
M2Device2Presencebooleantrue-CIC卡的M.2卡槽位2在位情况
说明:目前只有S920X05的CIC卡支持
RetimerVersion [ {arraytrue-指定扩展板卡上的Retimer芯片固件版本号:
● Version:固件版本号
● PositionId:Retimer芯片的位号
RetimerVersion[].Versionstringtrue-固件版本号
RetimerVersion[].PositionIdstringtrue-Retimer芯片的位号
} ]
Actionsnulltrue-指定扩展板卡上的统一动作接口
CSRVersionstringtrue-指定扩展板卡上的CSR文件版本号
说明
openUBMC 25.12 LTS及以上版本支持
NpuNamestringtrue-指定扩展板卡的NPU型号信息,只有ACU需要显示
ComputeCapabilitystringtrue-指定扩展板卡的算力信息,目前只有ACU需要显示
MulticLogic [ {arraytrue-指定扩展板卡上的逻辑器件信息:
● Version:逻辑器件版本号
● Name:逻辑器件名称
● PositionId:逻辑器件位号
MulticLogic[].Versionstringtrue-逻辑器件版本号
MulticLogic[].PositionIdnumbertrue-逻辑器件位号
MulticLogic[].Namestringtrue-逻辑器件名称
} ]
Linksobjecttrue-扩展板卡资源关联的资源
MultiLogic[ ]arraytrue-指定扩展板卡上所有逻辑器件信息显示,包含cpld与fpga:
Version:逻辑器件版本号
PositionId:逻辑器件位号
Name:逻辑器件名称
Processors[ ]arraytrue-指定NPU板卡关联的NPU资源信息
Oem {objecttrue-自定义属性
}

supported_methods ​

  • GET
  • PATCH
  • POST

HTTP methods ​

GET ​

命令功能

查询指定扩展板卡资源信息

命令格式

URL: https://device_ip/redfish/v1/Chassis/chassis_id/Boards/board_id

请求头:

text
X-Auth-Token: 123456789***********************

请求消息体: 无

参数说明

参数参数说明取值
device_ip登录设备的IP地址IPv4或IPv6地址
chassis_id机箱资源的ID● 针对机架服务器,取值为1
● 针对高密服务器,取值为BladeN(N表示节点槽位号),例如 "Blade1"
● 针对刀片服务器,取值可以为BladeN(N表示计算节点槽位号)或SwiN(N表示交换模块槽位号),例如 "Swi1"
● 针对X6800 V5,X6000 V5,G5500,XA320 V2服务器,取值还可以为Enc,表示计算节点所在的机框资源
● 针对设备U位信息,取值可以为UN(N表示设备U位号),例如"U1"
● 针对机柜资源,取值为Rack
board_id扩展板资源的ID可通过扩展板卡集合资源获取。
auth_value执行该GET请求时,必须在"Headers"中携带"X-Auth-Token"值用于鉴权可通过/redfish/v1/SessionService/Sessions创建会话时获得

使用指南

无

使用实例

请求样例1:

http
GET <https://device_ip/redfish/v1/Chassis/1/Boards/chassisMainBoard>

请求头:

text
X-Auth-Token: 123456789***********************

请求消息体:无

响应样例:

json
{
"@odata.context": "/redfish/v1/$metadata#HwBoard.HwBoard",
"@odata.id": "/redfish/v1/Chassis/1/Boards/chassisMainBoard",
"@odata.type": "#HwBoard.v1_0_0.HwBoard",
"Id": "chassisMainBoard",
"Description": "MainBoard",
"Name": "chassisMainBoard",
"CardNo": 0,
"Status": {
"Health": "OK",
"Severity": "Informational",
"State": "Enabled"
},
"DeviceLocator": "MainBoard",
"DeviceType": "MainBoard",
"Location": "chassis",
"Manufacturer": "",
"ProductName": null,
"SerialNumber": "022JRVCNGB004253",
"PartNumber": "03022JRV",
"AssetTag": "%22",
"CPLDVersion": "1.11(U46)",
"PCBVersion": ".E",
"BoardName": "BC11HGSB",
"BoardId": "0x000e",
"ComponentUniqueID": null,
"ManufactureDate": "2016/11/16 Wed 20:23:00",
"AssociatedResource": null,
"PositionId": null,
"PowerWatts": null,
"LinkWidthAbility": null,
"LinkSpeedAbility": null,
"LinkWidth": null,
"LinkSpeed": null,
"PchModel": null,
"SupportedRAIDLevels": null,
"FirmwareVersion": "0.05",
"WorkMode": null,
"M2Device1Presence": null,
"M2Device2Presence": null,
"Actions": null,
"CSRVersion": null,
"NpuName": null,
"ComputeCapability": null,
"MulticLogic": [
{
"Version": "1.14",
"Name": "CPLD1",
"PositionId": 6288
},
{
"Version": "1.15",
"Name": "CPLD2",
"PositionId": 6293
}
],
"RetimerVersion": [
{
"PositionId": "U123",
"Version": "device_ip"
},
{
"PositionId": "U125",
"Version": "device_ip"
}
]
}

响应码:200

请求样例2:

http
GET <https://device_ip/redfish/v1/Chassis/1/Boards/ACU1NpuBoard1>

请求头:

text
X-Auth-Token: 123456789***********************

请求消息体:无

响应样例:

json
{
"@odata.context": "/redfish/v1/$metadata#HwBoard.HwBoard",
"@odata.id": "/redfish/v1/Chassis/1/Boards/ACU1NpuBoard1",
"@odata.type": "#HwBoard.v1_0_0.HwBoard",
"Id": "ACU1NpuBoard1",
"Description": "NpuBoard",
"Name": "ACU1NpuBoard1",
"CardNo": 0,
"Status": {
"Health": "OK",
"Severity": "Informational",
"State": "Enabled"
},
"DeviceLocator": "MainBoard",
"DeviceType": "MainBoard",
"Location": "chassis",
"Manufacturer": "",
"ProductName": null,
"SerialNumber": "022JRVCNGB004253",
"PartNumber": "03022JRV",
"AssetTag": "%22",
"CPLDVersion": "1.11(U46)",
"PCBVersion": ".E",
"BoardName": "BC11HGSB",
"BoardId": "0x000e",
"ComponentUniqueID": null,
"ManufactureDate": "2016/11/16 Wed 20:23:00",
"AssociatedResource": null,
"PositionId": null,
"PowerWatts": null,
"LinkWidthAbility": null,
"LinkSpeedAbility": null,
"LinkWidth": null,
"LinkSpeed": null,
"PchModel": null,
"SupportedRAIDLevels": null,
"FirmwareVersion": "0.05",
"WorkMode": null,
"M2Device1Presence": null,
"M2Device2Presence": null,
"Actions": null,
"CSRVersion": null,
"NpuName": null,
"ComputeCapability": null,
"MulticLogic": [
{
"Version": "1.14",
"Name": "CPLD1",
"PositionId": 6288
},
{
"Version": "1.15",
"Name": "CPLD2",
"PositionId": 6293
}
],
"RetimerVersion": [
{
"PositionId": "U123",
"Version": "device_ip"
},
{
"PositionId": "U125",
"Version": "device_ip"
}
],
"Oem": {
"Public": {
"Actions": {
"#NpuBoard.NpuBoardReset": {
"target": "/redfish/v1/Chassis/1/Boards/ACU1NpuBoard1/Actions/NpuBoard.NpuBoardReset",
"@Redfish.ActionInfo": "/redfish/v1/Chassis/1/Boards/ACU1NpuBoard1/NpuBoardResetActionInfo"
}
}
}
}
}

响应码:200

PATCH ​

命令功能

修改指定拓展板卡资源属性

命令格式

URL: https://device_ip/redfish/v1/Chassis/chassis_id/Boards/board_id

请求头:

text
X-Auth-Token: 123456789***********************

请求消息体:

json
{
"WorkMode": mode
}

URL参数说明

参数参数说明取值
chassis_id机箱资源的ID● 针对机架服务器,取值为1
● 针对高密服务器,取值为BladeN(N表示节点槽位号),例如 "Blade1"
● 针对刀片服务器,取值可以为BladeN(N表示计算节点槽位号)或SwiN(N表示交换模块槽位号),例如 "Swi1"
● 针对X6800 V5,X6000 V5,G5500,XA320 V2服务器,取值还可以为Enc,表示计算节点所在的机框资源
● 针对设备U位信息,取值可以为UN(N表示设备U位号),例如"U1"
● 针对机柜资源,取值为Rack
board_id扩展板资源的ID可通过扩展板卡集合资源获取。

请求头参数说明

参见 请求头参数说明

请求体参数说明

参数参数说明取值
WorkMode指定拓展板卡的工作模式AMP:独立模式 SMP:集成模式
说明:目前只有A800-9000,A800-9010及A300-9000的NPU卡支持

使用指南

无

使用实例

请求样例:

http
PATCH <https://device_ip/redfish/v1/Chassis/1/Boards/mainboardNPUBoard1>

请求头:

text
X-Auth-Token: 123456789***********************

请求消息体:

json
{
"WorkMode": "AMP"
}

响应样例:

json
{
"@odata.context": "/redfish/v1/$metadata#HwBoard.HwBoard",
"@odata.id": "/redfish/v1/Chassis/1/Boards/mainboardNPUBoard1",
"@odata.type": "#HwBoard.v1_0_0.HwBoard",
"Id": "mainboardNPUBoard1",
"Description": "GPUBoard",
"Name": "mainboardNPUBoard1",
"CardNo": 1,
"Status": {
"State": "Enabled",
"Severity": "Informational",
"Health": "OK"
},
"DeviceLocator": "NPUBoard1",
"DeviceType": "PCIeCardCarrierBoard",
"Location": "mainboard",
"Manufacturer": "",
"ProductName": null,
"SerialNumber": null,
"PartNumber": null,
"AssetTag": null,
"CPLDVersion": "1.00",
"PCBVersion": ".C",
"BoardName": "IT21SD4A",
"BoardId": "0x0093",
"ComponentUniqueID": null,
"ManufactureDate": "1996/01/01 Mon 00:00:00",
"AssociatedResource": null,
"PositionId": "U1152",
"PowerWatts": null,
"SupportedRAIDLevels": null,
"PchModel": null,
"LinkWidthAbility": null,
"LinkSpeedAbility": null,
"LinkWidth": null,
"LinkSpeed": null,
"WorkMode": "AMP",
"M2Device1Presence": null,
"M2Device2Presence": null,
"RetimerVersion": [
{
"PositionId": "U123",
"Version": "device_ip"
},
{
"PositionId": "U125",
"Version": "device_ip"
}
]
}

响应码:200

POST (ACTION) ​

NpuReset ​

命令功能

NPU 模组复位

命令格式

URL: https://device_ip/redfish/v1/Chassis/chassis_id/Boards/board_id/Actions/NPUBoard.NPUBoardReset

请求头:

text
X-Auth-Token: 123456789***********************
Content-Type: header_type

请求消息体:

json
{
"DomainId": domain_id
}

请求头参数说明

参见 请求头参数说明

请求体参数说明

参数参数说明取值
chassis_id机箱资源的ID● 针对机架服务器,取值为1
● 针对高密服务器,取值为BladeN(N表示节点槽位号),例如 "Blade1"
● 针对刀片服务器,取值可以为BladeN(N表示计算节点槽位号)或SwiN(N表示交换模块槽位号),例如 "Swi1"
● 针对X6800 V5,X6000 V5,G5500,XA320 V2服务器,取值还可以为Enc,表示计算节点所在的机框资源
● 针对设备U位信息,取值可以为UN(N表示设备U位号),例如"U1"
● 针对机柜资源,取值为Rack
board_idNPU板资源的ID可通过NPU板卡集合资源获取。
domain_id可选字段,NPU复位域缺省:按照0处理 0:复位NPU模组全域 1:复位NPU模组计算单元
说明:仅A900 A5 SuperPoD, Atlas 850/850E 服务器支持该属性

使用指南

无

使用实例

请求样例:

http
POST /redfish/v1/Chassis/1/Boards/ACU1NpuBoard1/Actions/NpuBoard.NpuBoardReset

请求头:

text
X-Auth-Token: 123456789***********************
Content-Type: application/json

请求消息体:

json
{
"DomainId": 1
}

响应样例:

json
{
"error": {
"code": "Base.1.0.GeneralError",
"message": "A general error has occurred. See ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"@odata.type": "/redfish/v1/$metadata#MessageRegistry.1.0.0.MessageRegistry",
"MessageId": "Base.1.0.Success",
"RelatedProperties": [],
"Message": "Successfully Completed Request",
"MessageArgs": [],
"Severity": "OK",
"Resolution": "None"
}
]
}
}

响应码:200