代码仓
中
Set PEF Configuration Parameters
更新时间: 2025/06/26
在AtomGit上查看源码

12h-设置PEF配置参数(Set-PEF-Configuration-Parameters) ​

修订记录 ​

openUBMC版本号修订日期修订人修订内容
25.062025/06/26pengqiang-gs初稿,新增命令详情

基本信息 ​

功能说明 ​

设置 PEF 的配置参数以及事件的 strings。 This command is used for setting parameters such as PEF enable/disable and for entering the configuration of the Event Filter table and the Alert Strings.

权限 ​

ReadOnly

命令信息 ​

请求信息 ​

字节顺序域取值说明
1Parameter selector
[7] - reserved
[6:0] - Parameter selector
2Configuration parameter data, per PEF Configuration Parameters.

响应信息 ​

字节顺序域取值说明
1Completion Code. Generic plus the following command-specific completion codes:
80h = parameter not supported.
81h = attempt to set the ‘set in progress’ value (in parameter #0) when not in the ‘set complete’ state. (This completion code provides a way to recognize that another party has already ‘claimed’ the parameters)
82h = attempt to write read-only parameter
83h = attempt to read write-only parameter

命令样例 ​

样例1:设置 PEF 的配置参数 ​

  • 请求:
  • 响应:

返回到索引 ​