代码仓
中
Set Fan Level
更新时间: 2025/06/26
在AtomGit上查看源码

15h-设置风扇等级(Set-Fan-Level) ​

修订记录 ​

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息 ​

功能说明 ​

设置风扇等级。

权限 ​

BasicSetting

命令信息 ​

请求信息 ​

字节顺序域取值说明
NetFnPICMG 2Ch
CMD15h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.
2FRU Device ID. Indicates an individual FRU device to query.
3Fan Level. To be accepted, this value is:- greater than or equal to Minimum Speed Level and less than or equal to Maximum Speed Level.- FEh (Shut Down)- FFh (Local Control).
(4)Local Control Enable State[1]. This field is optional. Set this to 0 to disable, or 1 to enable, Local Control mode.

响应信息 ​

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.

命令样例 ​

设置风扇等级 ​

请求:

ipmicmd -k "0f 00 2c 15 00 00 ff" smi 0

响应:

0f 2d 00 15 00 00

说明:本例响应的完成码为 00(成功)。将 FRU 0 的风扇等级设为 FFh(本地控制),不携带可选的 Local Control Enable State 字节;本例要求设备支持本地控制。

返回到索引 ​