10h-计算功率属性(Compute-Power-Properties) ​

修订记录 ​

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息 ​

功能说明 ​

计算功率属性。

权限 ​

命令信息 ​

请求信息 ​

字节顺序域取值说明
NetFnPICMG 2Ch
CMD10h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used
2FRU Device ID. Indicates an individual FRU device to lock in the power properties

响应信息 ​

字节顺序域取值说明
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used
3Number of Spanned Slots. Indicates the total number of Slots spanned by the Board. This is 1 for a Board that inserts into a single Slot and any non-Board FRU
4IPM Controller Location. When a Board spans more than one Slot (a multi-Slot Board), the Shelf Manager needs to know which Slot contains the IPM Controller. This number treats the left most Slot location of the multi-Slot Board as 0 and increment by single units moving to the right.
This value is 0 for a Board that inserts into a single Slot and any non- Board FRU. This value represents the location of the Zone 1 connection for the Board

命令样例 ​

计算功率属性 ​

请求:

ipmicmd -k "0f 00 2c 10 00 00" smi 0

响应:

0f 2d 00 10 00 00 * *

说明:本例响应的完成码为 00(成功)。选择 FRU 0。两个 * 分别表示设备实际跨越的槽位数量和 IPM 控制器位置字节。