Query Pangea Interface Card EEPROM Data
更新时间: 2026/10/26
在AtomGit上查看源码BBh-查询Pangea接口卡EEPROM数据(Query-Pangea-Interface-Card-EEPROM-Data)
修订记录
| openUBMC版本号 | 修订日期 | 修订内容 |
|---|---|---|
| 25.06 | 2025/06/26 | 初稿,新增命令详情 |
基本信息
功能说明
查询Pangea接口卡EEPROM数据。
权限
READONLY
适用机型
2ULB1220V6、NST1240V6_NST1220V6
命令信息
请求信息
| 参数(字节) | 域取值说明 |
|---|---|
| NetFn | 32h |
| CMD | bbh |
| 1 | {slot_id} |
| 2 | 0x01 |
| 3:4 | 全填0 |
| 5 | sdrtype,填0x85 |
| 6:7 | offset(LS Byte first) |
| 8 | length |
响应信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | Completion Code |
| 2:224 | EepromData |
命令样例
查询1号槽位Pangea接口卡EEPROM数据
请求:
text
ipmitool raw 0x32 0xbb 0x01 0x01 0x00 0x00 0x85 0x00 0x00 0Xe0响应:
text
01 02 03 04 05 06 07 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00