代码仓
中
Set Chassis Capabilities
更新时间: 2025/06/26
在AtomGit上查看源码

05h-设置机箱能力(Set-Chassis-Capabilities) ​

修订记录 ​

openUBMC版本号修订日期修订内容
25.062025/06/26初稿,新增命令详情

基本信息 ​

功能说明 ​

设置机箱功能。

权限 ​

命令信息 ​

请求信息 ​

字节顺序域取值说明
NetFnChassis 00h
CMD05h
1


Capabilities Flags
[7:2]- reserved
[1]- 1b=Provides Front Panel Lockout.
[0]- 1b=Provides intrusion
2Chassis FRU Info Device Address (see Get Chassis Capabilities for a description of these addresses, their use, and the field formatting.)
3Chassis SDR Device Address
4Chassis SEL Device Address
5Chassis SM Device Address
(6)Chassis Bridge Device Address

响应信息 ​

字节顺序域取值说明
1Completion Code. Note, this command does not return an error completion code if an attempt is made to change a 'read-only' parameter
Software must check which fields in the response match the value from the request by using the Get Chassis Capabilities command

命令样例 ​

设置机箱功能 ​

请求:

ipmicmd -k "0f 00 00 05 03 20 20 20 20 20" smi 0

响应:

0f 01 00 05 00

说明:本例响应的完成码为 00(成功)。能力标志选择前面板锁定和入侵检测,FRU、SDR、SEL、系统管理及桥设备地址均选择 20h。