Obtain the sensor alarm status
更新时间: 2025/06/26
在Gitcode上查看源码B1h-获取sensor告警状态(Obtain-the-sensor-alarm-status)
修订记录
| openUBMC版本号 | 修订日期 | 修订内容 |
|---|---|---|
| 25.06 | 2025/06/26 | 初稿,新增命令详情 |
基本信息
功能说明
获取sensor告警状态。
权限
ReadOnly
适用机型
CST0221V6、CST0210V6
命令信息
请求信息
| 字节顺序 | 域取值说明 |
|---|---|
| NetFn | 32h |
| CMD | B1h |
| 1 | Fru id |
| 2:3 | Fru type 0x0002 控制板 0x0004 BBU 0x0001 接口卡(CST0221V6) |
| 4 | Device id |
| 5 | Sdr type 0x1 温度 0x2 电压 |
| 6 | Need num |
响应信息
| 字节顺序 | 域取值说明 |
|---|---|
| 1 | Completion Code |
| 2:(need_num*4+1) | Sensor alarm state |
命令样例
获取sensor告警状态
请求:
ipmitool raw 0x32 0xb1 0x00 0x02 0x00 0x00 0x01 0x10响应:
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00