ipmcset -d psuworkmode
更新时间: 2026/07/16
在Gitcode上查看源码ipmcset -d psuworkmode
命令功能
设置 PSU 工作模式
命令格式
text
ipmcset -d psuworkmode -v <option> [active psuid|enabled/disabled]参数说明
| Name | Location | Type | Required | Default | Constraint | Description |
|---|---|---|---|---|---|---|
value1 | ReqBody | - | 否 | - | - | - |
value2 | ReqBody | - | 否 | - | - | - |
value3 | ReqBody | - | 否 | - | - | - |
响应/输出说明
| Name | Location | Type | Required | Default | Constraint | Description |
|---|---|---|---|---|---|---|
value1 | RspBody | - | 否 | - | - | - |
value2 | RspBody | - | 否 | - | - | - |
value3 | RspBody | - | 否 | - | - | - |
GetAllValueParamsValid | RspBody | - | 否 | - | - | - |
DeepSleepSupported | RspBody | - | 否 | - | - | - |
NormalAndRedundancy | RspBody | - | 否 | - | - | - |
OnePowerList | RspBody | - | 否 | - | - | - |
后端处理流
| Step | Type | Path/URI | Interface | Field/Method | Source | Destination |
|---|---|---|---|---|---|---|
| 1 | Property | /bmc/kepler/Systems/1/PowerStrategy | bmc.kepler.Systems.PowerStrategy | - | - | {"DeepSleepSupported": "DeepSleepSupported", "NormalAndRedundancy": "NormalAndRedundancy"} |
| 2 | List | /bmc/kepler/Systems/1/PowerMgmt | - | - | - | {"Members": "OnePowerList"} |
| 3 | Method | /bmc/kepler/Systems/1/PowerStrategy | bmc.kepler.Systems.PowerStrategy | SetPowerWorkingMode | - | - |
| 4 | Method | /bmc/kepler/Systems/1/PowerStrategy | bmc.kepler.Systems.PowerStrategy | SetPowerWorkingMode | - | - |
| 5 | Method | /bmc/kepler/Systems/1/PowerStrategy | bmc.kepler.Systems.PowerStrategy | SetPowerWorkingMode | - | - |
| 6 | Property | /bmc/kepler/Systems/1/PowerStrategy | bmc.kepler.Systems.PowerStrategy | - | {"DeepSleep": "${Statements/GetDeepSleepStatus()}"} | - |
使用示例
text
ipmcset -d psuworkmode -v <option> [active psuid|enabled/disabled]输出样例
| Scenario | Output | Source |
|---|---|---|
| 其他 | Usage: ipmcset -d psuworkmode -v <option> [active psuid|enabled/disabled] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | Usage: ipmcset -d psuworkmode -v <option> [active psuid|enabled/disabled] [active psuid] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | Options are: | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | 0: Load Balancing, without parameter [active psuid|enabled/disabled] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | 1: Active/Standby, with parameter [active psuid] range <<value>-<value>> | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | 2: Hibernate, with parameter [enabled/disabled] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | Usage: ipmcset -d psuworkmode -v <option> [active psuid] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | Usage: ipmcset -d psuworkmode -v <option> [active psuid] [active psuid] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | Options are: | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | 0: Load Balancing, without parameter [active psuid] | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | 1: Active/Standby, [active psuid] range <<value>-<value>> | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 成功 | Enable Power Work Mode Hibernate successfully. | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 成功 | Disable Power Work Mode Hibernate successfully. | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 其他 | The normal and redundancy is enabled through the Redfish interface, this mode cannot be set. | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 成功 | Set Power Work Mode Load Balancing successfully. | interface_config/cli/echoes/ipmcset/_psuworkmode |
| 成功 | Set Power Work Mode Active Standby successfully. | interface_config/cli/echoes/ipmcset/_psuworkmode |
来源信息
| Item | Value |
|---|---|
| 命令类型 | ipmcset |
| target | _ |
| dataitem | psuworkmode |
| URI | /cli/v1/_/psuworkmode |
| Interface Type | Patch |
| 配置来源 | interface_config/cli/ipmcset/target.json |
| 请求版本 | 26.06_2026.06.30 |
| 源码提交 | 5606349e |