ipmcset -t storage -d ctrlconfig
更新时间: 2026/07/28
在Gitcode上查看源码

返回总览

命令功能

设置 RAID 控制器配置

命令格式

ipmcset -t storage -d ctrlconfig -v <RAID Controller ID> <[-cb <enabled|disabled>] [-smartercb <enabled|disabled>] [-jbod <enabled|disabled>] [-mode <RAID|HBA|JBOD|Mixed>] [-restore]>

命令类型

ipmcset

参数说明

NameTypeRequiredDefaultConstraintDescription
ControlIdnumber-Type: Range; 0, 255-v <RAID Controller ID> The RAID controller which will be set. It is mandatory.
CopyBackState--Type: Enum; Enum: enabled, disabled, default-cb <enabled│disabled> Set RAID controller Copyback to be enabled or disabled. enabled = Enable RAID controller Copyback disabled = Disable RAID controller Copyback
SmarterCopyBackState--Type: Enum; Enum: enabled, disabled, default-smartercb <enabled│disabled> Set RAID controller Copyback on SMART error to be enabled or disabled. It will be disabled when 'Copyback' is disabled. enabled = Enable RAID controller Copyback on SMART error. It can be enabled only when Copyback is enabled disabled = Disable RAID controller Copyback on SMART error
JBODState--Type: Enum; Enum: enabled, disabled, default-jbod <enabled│disabled> Set RAID controller JBOD to be enabled or disabled. enabled = Enable RAID controller JBOD mode disabled = Disable RAID controller JBOD mode
WorkModestring-Type: Enum; Enum: RAID, JBOD, HBA, Mixed, default-mode <RAID│HBA│JBOD│Mixed> Set RAID controller working mode.
Restore----restore Restore RAID controller settings. It can't be specified with other options simultaneously but mode.

使用示例

ipmcset -t storage -d ctrlconfig -v 0 -cb enabled -smartercb enabled -jbod enabled -mode RAID
ipmcset -t storage -d ctrlconfig -v 0 -restore

输出样例

Set RAID controller Copyback state successfully.
Set RAID controller Copyback state on SMART error successfully.
Set RAID controller JBOD mode successfully.
Set RAID controller mode successfully.
Restore RAID controller settings successfully.

配置来源

interface_config/cli/ipmcset/storage.json