ipmcget -t storage -d ctrlinfo
更新时间: 2026/07/16
在Gitcode上查看源码

ipmcget -t storage -d ctrlinfo

返回总览 | 返回命令索引

命令功能

查询 RAID 控制器信息

命令格式

text
ipmcget -t storage -d ctrlinfo -v <Option>

参数说明

NameLocationTypeRequiredDefaultConstraintDescription
OptionReqBody---all - Show all RAID controllers. ID - Show one RAID controller with this ID(An non-negative integer base 0). eg. 0,1,2...

响应/输出说明

NameLocationTypeRequiredDefaultConstraintDescription
OptionRspBody----
GetControllerListRspBody----

后端处理流

StepTypePath/URIInterfaceField/MethodSourceDestination
1List/bmc/kepler/Systems/1/Storage/Controllersbmc.kepler.Systems.Storage.Controller--{"Members": "ControllerList"}

使用示例

text
ipmcget -t storage -d ctrlinfo -v <Option>

输出样例

ScenarioOutputSource
其他PHY Status :interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他PHY #<value> :interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Unavailableinterface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他BBU Status : Absentinterface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他BBU Status : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他BBU Type : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他BBU Health : N/Ainterface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他BBU Health : <value>[1;32m<value>[0minterface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他BBU Health : <value>[1;31m<value>[0minterface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Details:interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他RAID Controller #<value> Informationinterface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他----------------------------------------------------------------------interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Name : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Type : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Component Name : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Support Out-of-Band Management : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Supported RAID Levels : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Driver Name : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Driver Type : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Mode : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Health : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Firmware Version : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他NVDATA Version : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Hardware Revision : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Memory Size : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Device Interface : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他SAS Address : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Minimum Strip Size Supported : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Maximum Strip Size Supported : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Spare Activation Mode : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Host bus link Width : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他No-Battery Write Cache : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Read Cache Percentage : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Configured Drives Write Cache Policy : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Unconfigured Drives Write Cache Policy : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他HBA Drives Write Cache Policy : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Controller Cache Is Pinned : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
失败Maintain PD Fail History across Reboot : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Copyback Enabled : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
失败Copyback on SMART error Enabled : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他JBOD Enabled : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他DDR ECC Count : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Boot Devices : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Primary Boot Device : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他Secondary Boot Device : <value>interface_config/cli/echoes/ipmcget/storage_ctrlinfo
其他----------------------------------------------------------------------interface_config/cli/echoes/ipmcget/storage_ctrlinfo

来源信息

ItemValue
命令类型ipmcget
targetstorage
dataitemctrlinfo
URI/cli/v1/storage/ctrlinfo
Interface TypeGet
配置来源interface_config/cli/ipmcget/storage.json
请求版本26.06_2026.06.30
源码提交5606349e
生成时间2026-07-16T01:48:37