代码仓
中
2.235.1.1.500.11.12 hwMezzCardEvent
更新时间: 2026/06/18
在AtomGit上查看源码

2.235.1.1.500.11.12 hwMezzCardEvent ​

Revision History ​

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview ​

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwMezzCardEvent
  • Relative OID: 2.235.1.1.500.11.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 12

Object Definitions ​

Scalar objects and notifications defined under this node.

hwMezzCardOverTempMinor ​

  • Relative OID: 2.235.1.1.500.11.12.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 1
  • Description: Mezzanine card overheating minor alarm. (Generated)

hwMezzCardOverTempMinorDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 2
  • Description: Mezzanine card overheating minor alarm. (Cleared)

hwMezzCardOverTempMajor ​

  • Relative OID: 2.235.1.1.500.11.12.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 3
  • Description: Mezzanine card overheating major alarm. (Generated)

hwMezzCardOverTempMajorDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 4
  • Description: Mezzanine card overheating major alarm. (Cleared)

hwMezzCardUncorrectableErr ​

  • Relative OID: 2.235.1.1.500.11.12.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 5
  • Description: Mezzanine card MCE/AER error. (Generated)

hwMezzCardUncorrectableErrDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 6
  • Description: Mezzanine card MCE/AER error. (Cleared)

hwMezzCardAccessTempFailure ​

  • Relative OID: 2.235.1.1.500.11.12.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 7
  • Description: Failed to read mezzanine card temperature. (Generated)

hwMezzCardAccessTempFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 8
  • Description: Failed to read mezzanine card temperature. (Cleared)

hwMezzCardAccessFRULableFailure ​

  • Relative OID: 2.235.1.1.500.11.12.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 9
  • Description: Failed to read mezzanine card electronic label. (Generated)

hwMezzCardAccessFRULableFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.10
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 10
  • Description: Failed to read mezzanine card electronic label. (Cleared)

hwMezzCardOverVoltage ​

  • Relative OID: 2.235.1.1.500.11.12.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 11
  • Description: Mezzanine card overvoltage major alarm. (Generated)

hwMezzCardOverVoltageDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 12
  • Description: Mezzanine card overvoltage major alarm. (Cleared)

hwMezzCardLowerVoltage ​

  • Relative OID: 2.235.1.1.500.11.12.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 13
  • Description: Mezzanine card undervoltage major alarm. (Generated)

hwMezzCardLowerVoltageDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.14
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 14
  • Description: Mezzanine card undervoltage major alarm. (Cleared)

hwMezzCardSVIDChipFailure ​

  • Relative OID: 2.235.1.1.500.11.12.31
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.31
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 31
  • Description: Mezzanine card failed to obtain WFR chip SVID. (Generated)

hwMezzCardSVIDChipFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.32
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.32
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 32
  • Description: Mezzanine card failed to obtain WFR chip SVID. (Cleared)

hwMezzCardVoltageFailure ​

  • Relative OID: 2.235.1.1.500.11.12.33
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.33
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 33
  • Description: Failed to read mezzanine card voltage. (Generated)

hwMezzCardVoltageFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.34
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.34
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 34
  • Description: Failed to read mezzanine card voltage. (Cleared)

hwMezzCardCEHardFailure ​

  • Relative OID: 2.235.1.1.500.11.12.35
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.35
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 35
  • Description: Mezzanine card health status degradation detected by PFAE. (Generated)

hwMezzCardCEHardFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.12.36
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.36
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 36
  • Description: Mezzanine card health status degradation detected by PFAE. (Cleared)

hwMezzCardNotInstalled ​

  • Relative OID: 2.235.1.1.500.11.12.37
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.12.37
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMezzCardEvent 37
  • Description: The mezzanine card is not installed.

Back to index ​