2.235.1.1.500.11.15 hwMemoryBoardEvent
更新时间: 2026/06/18
在AtomGit上查看源码

2.235.1.1.500.11.15 hwMemoryBoardEvent ​

Revision History ​

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview ​

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwMemoryBoardEvent
  • Relative OID: 2.235.1.1.500.11.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 15

Object Definitions ​

Scalar objects and notifications defined under this node.

hwMemoryBoardLowerTemp ​

  • Relative OID: 2.235.1.1.500.11.15.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMemoryBoardEvent 1
  • Description: Memory board undertemperature. (Generated)

hwMemoryBoardLowerTempDeassert ​

  • Relative OID: 2.235.1.1.500.11.15.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMemoryBoardEvent 2
  • Description: Memory board undertemperature. (Cleared)

hwMemoryBoardAccessTempFailure ​

  • Relative OID: 2.235.1.1.500.11.15.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMemoryBoardEvent 3
  • Description: Failed to read memory board temperature. (Generated)

hwMemoryBoardAccessTempFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.15.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMemoryBoardEvent 4
  • Description: Failed to read memory board temperature. (Cleared)

hwMemoryBoardSMI2TainingError ​

  • Relative OID: 2.235.1.1.500.11.15.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMemoryBoardEvent 5
  • Description: Initialization error on SMI2 link of memory board. (Generated)

hwMemoryBoardSMI2TainingErrorDeassert ​

  • Relative OID: 2.235.1.1.500.11.15.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.15.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwMemoryBoardEvent 6
  • Description: Initialization error on SMI2 link of memory board. (Cleared)

Back to index ​