代码仓
中
2.235.1.1.500.11.85 hwLeakageDetectionCardEvent
更新时间: 2026/06/18
在AtomGit上查看源码

2.235.1.1.500.11.85 hwLeakageDetectionCardEvent ​

Revision History ​

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview ​

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwLeakageDetectionCardEvent
  • Relative OID: 2.235.1.1.500.11.85
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 85

Object Definitions ​

Scalar objects and notifications defined under this node.

hwLeakageDetectionCardValveNotDetected ​

  • Relative OID: 2.235.1.1.500.11.85.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 1
  • Description: The valve is not detected. (Generated)

hwLeakageDetectionCardValveNotDetectedDeassert ​

  • Relative OID: 2.235.1.1.500.11.85.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 2
  • Description: The valve is not detected. (Cleared)

hwLeakageDetectionCardValveOpeningStateException ​

  • Relative OID: 2.235.1.1.500.11.85.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 3
  • Description: An exception of the valve opening state is detected. (Generated)

hwLeakageDetectionCardValveOpeningStateExceptionDeassert ​

  • Relative OID: 2.235.1.1.500.11.85.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 4
  • Description: An exception of the valve opening state is detected. (Cleared)

hwLeakageDetectionCardValveInspectionException ​

  • Relative OID: 2.235.1.1.500.11.85.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 5
  • Description: An exception of the valve inspection is detected. (Generated)

hwLeakageDetectionCardValveInspectionExceptionDeassert ​

  • Relative OID: 2.235.1.1.500.11.85.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 6
  • Description: An exception of the valve inspection is detected. (Cleared)

hwLeakageDetectionCardValveFailure ​

  • Relative OID: 2.235.1.1.500.11.85.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 7
  • Description: The valve is faulty. (Generated)

hwLeakageDetectionCardValveFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.85.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.85.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwLeakageDetectionCardEvent 8
  • Description: The valve is faulty. (Cleared)

Back to index ​