2.235.1.1.500.11.65 hwGPUCarrierBoardEvent ​

Revision History ​

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview ​

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwGPUCarrierBoardEvent
  • Relative OID: 2.235.1.1.500.11.65
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 65

Object Definitions ​

Scalar objects and notifications defined under this node.

hwGPUCarrierBoardlowerVoltage ​

  • Relative OID: 2.235.1.1.500.11.65.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 1
  • Description: xPU carrier board voltage below lower major threshold. (Generated)

hwGPUCarrierBoardlowerVoltageDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 2
  • Description: xPU carrier board voltage below lower major threshold. (Cleared)

hwGPUCarrierBoardOverVoltage ​

  • Relative OID: 2.235.1.1.500.11.65.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 3
  • Description: xPU carrier board overvoltage major alarm. (Generated)

hwGPUCarrierBoardOverVoltageDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 4
  • Description: xPU carrier board overvoltage major alarm. (Cleared)

hwGPUCarrierBoardAccessVoltageFailure ​

  • Relative OID: 2.235.1.1.500.11.65.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 5
  • Description: Failed to obtain the voltage of xPU carrier board.(Generated)

hwGPUCarrierBoardAccessVoltageFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 6
  • Description: Failed to obtain the voltage of xPU carrier board.(Cleared)

hwGPUCarrierBoardOverTempMinor ​

  • Relative OID: 2.235.1.1.500.11.65.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 7
  • Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Generated)

hwGPUCarrierBoardOverTempMinorDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 8
  • Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Cleared)

hwGPUCarrierBoardAccessTempFailure ​

  • Relative OID: 2.235.1.1.500.11.65.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 9
  • Description: Failed to obtain the temperature at detection point on the xPU carrier board.(Generated)

hwGPUCarrierBoardAccessTempFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.10
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 10
  • Description: Failed to obtain the temperature at detection point on the xPU carrier board.(Cleared)

hwGPUCarrierBoardClockSignalLost ​

  • Relative OID: 2.235.1.1.500.11.65.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 11
  • Description: xPU carrier board clock signals lost.(Generated)

hwGPUCarrierBoardClockSignalLostDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 12
  • Description: xPU carrier board clock signals lost.(Cleared)

hwGPUCarrierBoardCPLDSelfTestFailure ​

  • Relative OID: 2.235.1.1.500.11.65.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 13
  • Description: xPU carrier board CPLD self-check error.(Generated)

hwGPUCarrierBoardCPLDSelfTestFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.14
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 14
  • Description: xPU carrier board CPLD self-check error.(Cleared)

hwGPUCarrierBoardAccessPowerFailure ​

  • Relative OID: 2.235.1.1.500.11.65.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.15
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 15
  • Description: Failed to obtain the power of xPU carrier board.(Generated)

hwGPUCarrierBoardAccessPowerFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.16
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 16
  • Description: Failed to obtain the power of xPU carrier board.(Cleared)

hwGPUCarrierBoardPowerOnFailure ​

  • Relative OID: 2.235.1.1.500.11.65.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 17
  • Description: Failed to power on xPU carrier board.(Generated)

hwGPUCarrierBoardPowerOnFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 18
  • Description: Failed to power on xPU carrier board.(Cleared)

hwGPUCarrierBoardInstalled ​

  • Relative OID: 2.235.1.1.500.11.65.19
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.19
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 19
  • Description: xPU carrier board installed.

hwGPUCarrierBoardRemoved ​

  • Relative OID: 2.235.1.1.500.11.65.21
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.21
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 21
  • Description: xPU carrier board removed.

hwGPUCarrierBoardMOSOverTemp ​

  • Relative OID: 2.235.1.1.500.11.65.23
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.23
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 23
  • Description: The soft-start circuit MOS FET temperature at detection point of xPU carrier board is too high. (Generated)

hwGPUCarrierBoardMOSOverTempDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.24
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.24
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 24
  • Description: The soft-start circuit MOS FET temperature at detection point of xPU carrier board is too high. (Cleared)

hwGPUCarrierBoardSoftStartPGAbnormal ​

  • Relative OID: 2.235.1.1.500.11.65.25
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.25
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 25
  • Description: The soft-start circuit power supply at detection point of xPU carrier board is abnormal. (Generated)

hwGPUCarrierBoardSoftStartPGAbnormalDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.26
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.26
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 26
  • Description: The soft-start circuit power supply at detection point of xPU carrier board is abnormal. (Cleared)

hwGPUCarrierBoardGPUThermalOver ​

  • Relative OID: 2.235.1.1.500.11.65.29
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.29
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 29
  • Description: MOS temperature on xPU carrier board exceeds the protection point. (Generated)

hwGPUCarrierBoardGPUThermalOverDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.30
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.30
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 30
  • Description: MOS temperature on xPU carrier board exceeds the protection point. (Cleared)

hwGPUCarrierBoardOverTempMajor ​

  • Relative OID: 2.235.1.1.500.11.65.31
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.31
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 31
  • Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Generated)

hwGPUCarrierBoardOverTempMajorDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.32
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.32
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 32
  • Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Cleared)

hwGPUCarrierBoardCEHardFailure ​

  • Relative OID: 2.235.1.1.500.11.65.37
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.37
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 37
  • Description: xPU carrier board health status degradation detected by PFAE.(Generated)

hwGPUCarrierBoardCEHardFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.38
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.38
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 38
  • Description: xPU carrier board health status degradation detected by PFAE.(Cleared)

hwGPUCarrierBoardReplaced ​

  • Relative OID: 2.235.1.1.500.11.65.39
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.39
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 39
  • Description: GPU board replaced.(Generated)

hwGPUCarrierBoardUCEHardFailure ​

  • Relative OID: 2.235.1.1.500.11.65.41
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.41
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 41
  • Description: xPU carrier board has triggered an uncorrectable error.(Generated)

hwGPUCarrierBoardUCEHardFailureDeassert ​

  • Relative OID: 2.235.1.1.500.11.65.42
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.65.42
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwGPUCarrierBoardEvent 42
  • Description: xPU carrier board has triggered an uncorrectable error.(Cleared)

Back to index ​