代码仓
中
Get PEF Configuration Parameters
更新时间: 2025/06/26
在AtomGit上查看源码

13h — Get PEF Configuration Parameters ​

Change History ​

openUBMC VersionRevision DateAuthorDescription
25.062025/06/26pengqiang-gsInitial draft, add command details

Basic Information ​

Function Description ​

Queries PEF configuration parameters and event strings.

Privilege ​

ReadOnly

Command Information ​

Request Information ​

ByteData Field
1[7]
 1b = get parameter revision only.
 0b = get parameter
[6:0] - Parameter selector
2Set Selector (00h if parameter does not require a Set Selector)
3Block Selector (00h if parameter does not require a block number)

Response Information ​

ByteData Field
1Completion Code. Generic plus the following command-specific completion codes:
80h = parameter not supported.
2[7:0] - Parameter revision.
Format: MSN = present revision. LSN = oldest revision parameter is backward compatible with. 11h for parameters in this specification
(3:N)The following data bytes are not returned when the 'get parameter revision only' bit is 1b.

Configuration parameter data, per PEF Configuration Parameters. If the rollback feature is implemented, the BMC makes a copy of the existing parameters when the 'set in progress' state becomes asserted (See the Set In Progress parameter #0). While the 'set in progress' state is active, the BMC will return data from this copy of the parameters, plus any uncommitted changes that were made to the data. Otherwise, the BMC returns parameter data from non-volatile storage.

Command Examples ​

Example 1: Get PEF Configuration Parameters ​

  • Request:
  • Response:

Back to Index ​