Renegotiate Power
更新时间: 2026/08/06
在AtomGit上查看源码Renegotiate Power
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Re-negotiate power information.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | PICMG 2Ch |
| CMD | 13h |
| 1 | PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used. |
| (2) | Requesting FRU Device ID. This byte is optional. If this is present, it designates which FRU Device ID wishes to have power levels renegotiated. If this byte is not present, the Shelf Manager renegotiates with all FRUs under the requesting IPM Controller. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used. |
Command Example
Renegotiate power information.
Request:
bash
ipmicmd -k "0f 00 2c 13 00" smi 0Response:
text
0f 2d 00 13 00 00Note: The response completion code is 00 (success). Omit the optional FRU ID to renegotiate power for all FRUs under the requesting controller.