Function Description ​

Performs a loop test on a port.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMDb0h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = F0h
5Fun ID=0x02
600h : start
01h : get test result
7test time

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:8Test Progress
9:12Error packet

Command Example ​

Clear the electronic label. ​

Request:

bash
ipmicmd -k "0f 00 30 b0 db 07 00 f0 02 01 01" smi 0

Response:

text
0f 31 00 b0 00 db 07 00 * * * * * * * *

Example assuming command execution succeeds (completion code 00). The request selects function 02 and queries its test result (01), with test-time byte 01. Each * is one device-dependent byte: four bytes of test progress, then four bytes of error-packet data.