Get expander mode Command
更新时间: 2026/08/06
在AtomGit上查看源码Get expander mode Command
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the extender mode.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 97h |
| 1: 3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand = 03h |
| 5 | Parameter selector |
| 6 | Set Selector. Selects a given set of parameters under a given Parameter selector value. 00h if parameter doesn't use a Set Selector |
| 7 | Block Selector (00h if parameter does not require a block number, 16 Bytes Per block) |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code Generic codes, plus following command-specific completion code(s): 80h=parameter not supported 83h=no more data |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:N | Configuration parameter data |
Command Example
Obtain the extender mode.
Request:
bash
ipmicmd -k "0f 00 30 97 db 07 00 03 00 00 00" smi 0Response:
text