Set Firmware Active
更新时间: 2026/08/06
在AtomGit上查看源码Set Firmware Active
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Sets the active firmware.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=14h |
| 5 | FRU ID |
| 6 | Component ID: 00h CPLD 01h~FFh reseverd |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code 80h=Upgrading... 81h=The component is not upgraded. |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the active firmware.
Request:
bash
ipmicmd -k "0f 00 30 94 db 07 00 14 00 00" smi 0Response:
text
0f 31 00 94 00 db 07 00The example response assumes successful command execution (completion code 00). Activates the previously upgraded CPLD firmware on FRU 0.