代码仓
中
Get span slot mapping
更新时间: 2026/08/06
在AtomGit上查看源码

Get span slot mapping ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

This API is used to obtain cross-slot mappings.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1: 3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 0 Ah

Response Information ​

ByteData Field
1Completion Code
2: 4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:8span slot mapping. LSB first
[31] slot32 occupied
[30] slot31 occupied
......

Command Example ​

Obtain the cross-slot mapping. ​

Request:

bash
ipmicmd -k "0f 00 30 94 db 07 00 0a" smi 0

Response:

text
0f 31 00 94 00 db 07 00 * * * *

The example response assumes successful command execution (completion code 00). The four * values form the little-endian 32-bit slot-occupancy bitmap.

Back to Index ​