Set VNC Configuration
更新时间: 2026/08/06
在AtomGit上查看源码Set VNC Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This function is used to set VNC parameters.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=67h |
| 5 | Index. Currently, the value is 0. |
| 6 | Configuration items: 1: Set the VNC password. 2: Verify the VNC password. Other values: reserved |
| 7:8 | Reserved. |
| 9:10 | Field Data Length |
| 11:N | Data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the VNC password.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 67 00 01 00 00 08 00 45 78 61 6d 70 31 65 21" smi 0Response:
text
0f 31 00 93 00 db 07 00The example response assumes successful command execution (completion code 00). Sets the eight-byte ASCII example VNC password Examp1e!, index 0, item 1, data length 0008h.