Function Description
Sets the BMC system lock status.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=58h |
| 5 | System LockDown Status. System lock status 0: disabled 1: enabled |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Sub command, subcommand=00h |
| 2 | FRU device ID. The default value is 00. |
Command Example
Set the BMC system lock status.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 58 01" smi 0Response:
text
0f 31 00 93 00 db 07 00The example response assumes successful command execution (completion code 00). Enables system lockdown. The SetSysLockDownState implementation returns completion code and manufacturer ID; the subcommand/FRU fields in this page's response table do not describe that implementation.