Get SmartCooling Customized Inlet Environmen Range info
更新时间: 2026/08/06
在AtomGit上查看源码Get SmartCooling Customized Inlet Environmen Range info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the temperature of the air intake vent.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=46h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Querying the Number of Temperature Values: count |
| 6:6+count-1 | Data, reading count temperature values |
| 6+count : 6+2count | Data, corresponding fan speed percentage. The number of read fan speed values is count + 1. |
Command Example
Obtain the air intake vent temperature.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 46" smi 0Response:
text
0f 31 00 93 00 db 07 00 * *The example response assumes successful command execution (completion code 00). The first * is the one-byte count; the second represents the entire variable data field: count temperature bytes followed by count+1 fan-speed bytes, totaling 2×count+1 bytes. If the actual response data exceeds 36 bytes, use ipmitool as advised by the user guide.