Get total Temperature
更新时间: 2026/08/06
在AtomGit上查看源码Get total Temperature
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the overall temperature.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 0x26h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:6 | total temp number |
| 7 | temp type 1-dimm temp 2-sensor reading |
| 8:9 | temp index if temp type 1, tempindex=dimmindex if temp type 2, tempindex=sensorNum |
| 10 | temp value |
| 11:N | Repeat parameters 7 to 10. |
Command Example
Obtain the memory temperature.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 26" smi 0Response:
text
0f 31 00 93 00 db 07 00 * * *The example response assumes successful command execution (completion code 00). The first two * values each represent one byte of the temperature count; the last * represents the entire variable record area, whose length is four times that count. If the actual response data exceeds 36 bytes, use ipmitool as advised by the user guide.