Get Upgrade ROM SKU Number
更新时间: 2026/08/06
在AtomGit上查看源码Get Upgrade ROM SKU Number
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Query the SKU number when the ROM is upgraded.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 0x23h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | SKU number: 00h no upgrade ROM (no upgrade ROM is inserted) 01h 1 02h 2 ...... 09h 9 Other Reserved |
Command Example
Query the SKU number when the ROM is upgraded.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 23" smi 0Response:
text
0f 31 00 93 00 db 07 00 *The example response assumes successful command execution (completion code 00). * is the one-byte upgrade ROM SKU number.