Set test type
更新时间: 2026/08/06
在AtomGit上查看源码Set test type
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Sets the test flag.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 90h |
| 1 | Sub command, sub command=38h |
| 2 | FRU Device ID |
| 3 | test type: 0: BIOS memory aging test 1: equipment test roadmap ... Other values: reserved |
| 4 | 0: off 1:on |
| 5 | Parameter. This parameter is reserved for test types that do not involve parameters. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code 0: The command is executed successfully. |
Command Example
Set the equipment test roadmap.
Request:
bash
[root@localhost ~]# ipmicmd -k "0f 00 30 90 38 00 01 00 03" smi 0Response:
text
0f 31 00 90 00