Dft Get Component Properties
更新时间: 2026/08/06
在AtomGit上查看源码Dft Get Component Properties
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains component attributes.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 90h |
| 1 | Sub command, sub command=2Ch |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:8 | Supported Component Mask |
| 9:12 | Present Component Mask |
Command Example
DFT obtains component attributes.
Request:
bash
Request:
ipmicmd -k "0f 00 30 90 2c" smi 0
Response: