2.235.1.1.500.10.1810 hwSysNotice
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.10.1810 hwSysNotice
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwSysNotice - Relative OID:
2.235.1.1.500.10.1810 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.1810 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObject 1810
Object Definitions
Scalar objects and notifications defined under this node.
hwSystemWarmReset
- Relative OID:
2.235.1.1.500.10.1810.129 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.1810.129 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSysNotice 129 - Description: Uncorrectable system error. Unable to locate the specific failure, please warm reset the host to try to solve the problem
hwSystemWarmResetDeassert
- Relative OID:
2.235.1.1.500.10.1810.130 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.1810.130 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSysNotice 130 - Description: Uncorrectable system error deassert