2.235.1.1.500.11.21 hwSwitchModuleEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.21 hwSwitchModuleEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwSwitchModuleEvent - Relative OID:
2.235.1.1.500.11.21 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 21
Object Definitions
Scalar objects and notifications defined under this node.
hwSwitchModuleOverVoltage
- Relative OID:
2.235.1.1.500.11.21.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 1 - Description: Switch module overvoltage major alarm. (Generated)
hwSwitchModuleOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.21.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.2 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 2 - Description: Switch module overvoltage major alarm. (Cleared)
hwSwitchModuleLowerVoltage
- Relative OID:
2.235.1.1.500.11.21.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 3 - Description: Switch module voltage below lower major threshold. (Generated)
hwSwitchModuleLowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.21.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.4 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 4 - Description: Switch module voltage below lower major threshold. (Cleared)
hwSwitchModuleAccessVoltageFailure
- Relative OID:
2.235.1.1.500.11.21.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 5 - Description: Failed to read Switch module voltage. (Generated)
hwSwitchModuleAccessVoltageFailureDeassert
- Relative OID:
2.235.1.1.500.11.21.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 6 - Description: Failed to read Switch module voltage. (Cleared)
hwSwitchModuleClockPower
- Relative OID:
2.235.1.1.500.11.21.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 7 - Description: Power supplies to clock chips on the Switch module abnormal. (Generated)
hwSwitchModuleClockPowerDeassert
- Relative OID:
2.235.1.1.500.11.21.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.8 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 8 - Description: Power supplies to clock chips on the Switch module abnormal. (Cleared)
hwSwitchModuleClock
- Relative OID:
2.235.1.1.500.11.21.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 9 - Description: Switch module clock chips abnormal. (Generated)
hwSwitchModuleClockDeassert
- Relative OID:
2.235.1.1.500.11.21.10 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.10 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 10 - Description: Switch module clock chips abnormal. (Cleared)
hwSwitchModulePower
- Relative OID:
2.235.1.1.500.11.21.11 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.11 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 11 - Description: Switch module power signal abnormal. (Generated)
hwSwitchModulePowerDeassert
- Relative OID:
2.235.1.1.500.11.21.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.12 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 12 - Description: Switch module power signal abnormal. (Cleared)
hwSwitchModuleComponentOverTempMinor
- Relative OID:
2.235.1.1.500.11.21.13 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.13 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 13 - Description: Switch module component overtemperature minor alarm. (Generated)
hwSwitchModuleComponentOverTempMinorDeassert
- Relative OID:
2.235.1.1.500.11.21.14 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.14 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 14 - Description: Switch module component overtemperature minor alarm. (Cleared)
hwSwitchModuleComponentAccessTempFailure
- Relative OID:
2.235.1.1.500.11.21.15 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.15 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 15 - Description: Failed to obtain the component temperature of switch module. (Generated)
hwSwitchModuleComponentAccessTempFailureDeassert
- Relative OID:
2.235.1.1.500.11.21.16 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.16 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 16 - Description: Failed to obtain the component temperature of switch module. (Cleared)
hwSwitchModuleNPUToSwitchModuleLinkAbnormal
- Relative OID:
2.235.1.1.500.11.21.17 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.17 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 17 - Description: Abnormal link for the NPU to access the switch module component. (Generated)
hwSwitchModuleNPUToSwitchModuleLinkAbnormalDeassert
- Relative OID:
2.235.1.1.500.11.21.18 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.21.18 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchModuleEvent 18 - Description: Abnormal link for the NPU to access the switch module component. (Cleared)