2.235.1.1.500.11.32 hwSwitchMezzEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.32 hwSwitchMezzEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwSwitchMezzEvent - Relative OID:
2.235.1.1.500.11.32 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 32
Object Definitions
Scalar objects and notifications defined under this node.
hwSwitchMezzFault
- Relative OID:
2.235.1.1.500.11.32.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 5 - Description: Mezzanine card fault. (Generated)
hwSwitchMezzFaultDeassert
- Relative OID:
2.235.1.1.500.11.32.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 6 - Description: Mezzanine card fault. (Cleared)
hwSwitchMezz2V5LowerVoltage
- Relative OID:
2.235.1.1.500.11.32.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 7 - Description: Mezzanine card 2.5V undervoltage major alarm. (Generated)
hwSwitchMezz2V5LowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.8 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 8 - Description: Mezzanine card 2.5V undervoltage major alarm. (Cleared)
hwSwitchMezz2V5OverVoltage
- Relative OID:
2.235.1.1.500.11.32.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 9 - Description: Mezzanine card 2.5V overvoltage major alarm. (Generated)
hwSwitchMezz2V5OverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.10 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.10 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 10 - Description: Mezzanine card 2.5V overvoltage major alarm. (Cleared)
hwSwitchMezz3V3LowerVoltage
- Relative OID:
2.235.1.1.500.11.32.11 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.11 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 11 - Description: Mezzanine card 3.3V undervoltage major alarm. (Generated)
hwSwitchMezz3V3LowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.12 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 12 - Description: Mezzanine card 3.3V undervoltage major alarm. (Cleared)
hwSwitchMezz3V3OverVoltage
- Relative OID:
2.235.1.1.500.11.32.13 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.13 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 13 - Description: Mezzanine card 3.3V overvoltage major alarm. (Generated)
hwSwitchMezz3V3OverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.14 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.14 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 14 - Description: Mezzanine card 3.3V overvoltage major alarm. (Cleared)
hwSwitchMezz12VLowerVoltage
- Relative OID:
2.235.1.1.500.11.32.15 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.15 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 15 - Description: Mezzanine card 12V undervoltage major alarm. (Generated)
hwSwitchMezz12VLowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.16 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.16 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 16 - Description: Mezzanine card 12V undervoltage major alarm. (Cleared)
hwSwitchMezz12VOverVoltage
- Relative OID:
2.235.1.1.500.11.32.17 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.17 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 17 - Description: Mezzanine card 12V overvoltage major alarm. (Generated)
hwSwitchMezz12VOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.18 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.18 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 18 - Description: Mezzanine card 12V overvoltage major alarm. (Cleared)
hwSwitchMezz1VLowerVoltage
- Relative OID:
2.235.1.1.500.11.32.19 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.19 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 19 - Description: Mezzanine card 1V undervoltage major alarm. (Generated)
hwSwitchMezz1VLowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.20 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.20 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 20 - Description: Mezzanine card 1V undervoltage major alarm. (Cleared)
hwSwitchMezz1VOverVoltage
- Relative OID:
2.235.1.1.500.11.32.21 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.21 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 21 - Description: Mezzanine card 1V overvoltage major alarm. (Generated)
hwSwitchMezz1VOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.22 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.22 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 22 - Description: Mezzanine card 1V overvoltage major alarm. (Cleared)
hwSwitchMezz1V8LowerVoltage
- Relative OID:
2.235.1.1.500.11.32.23 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.23 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 23 - Description: Mezzanine card 1.8V undervoltage major alarm. (Generated)
hwSwitchMezz1V8LowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.24 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.24 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 24 - Description: Mezzanine card 1.8V undervoltage major alarm. (Cleared)
hwSwitchMezz1V8OverVoltage
- Relative OID:
2.235.1.1.500.11.32.25 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.25 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 25 - Description: Mezzanine card 1.8V overvoltage major alarm. (Generated)
hwSwitchMezz1V8OverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.26 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.26 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 26 - Description: Mezzanine card 1.8V overvoltage major alarm. (Cleared)
hwSwitchMezz1V5LowerVoltage
- Relative OID:
2.235.1.1.500.11.32.27 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.27 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 27 - Description: Mezzanine card 1.5V undervoltage major alarm. (Generated)
hwSwitchMezz1V5LowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.28 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.28 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 28 - Description: Mezzanine card 1.5V undervoltage major alarm. (Cleared)
hwSwitchMezz1V5OverVoltage
- Relative OID:
2.235.1.1.500.11.32.29 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.29 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 29 - Description: Mezzanine card 1.5V overvoltage major alarm. (Generated)
hwSwitchMezz1V5OverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.30 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.30 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 30 - Description: Mezzanine card 1.5V overvoltage major alarm. (Cleared)
hwSwitchMezzStdby3V3LowerVoltage
- Relative OID:
2.235.1.1.500.11.32.31 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.31 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 31 - Description: Mezzanine card standby 3.3V undervoltage major alarm. (Generated)
hwSwitchMezzStdby3V3LowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.32 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.32 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 32 - Description: Mezzanine card standby 3.3V undervoltage major alarm. (Cleared)
hwSwitchMezzStdby3V3OverVoltage
- Relative OID:
2.235.1.1.500.11.32.33 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.33 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 33 - Description: Mezzanine card standby 3.3V overvoltage major alarm. (Generated)
hwSwitchMezzStdby3V3OverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.32.34 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.34 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 34 - Description: Mezzanine card standby 3.3V overvoltage major alarm. (Cleared)
hwSwitchMezzNotInstalled
- Relative OID:
2.235.1.1.500.11.32.35 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.35 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 35 - Description: Mezzanine card not installed.
hwSwitchMezzPowerOff
- Relative OID:
2.235.1.1.500.11.32.37 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.37 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 37 - Description: Mezzanine card installed but powered off.
hwSwitchMezzReqPowerOn
- Relative OID:
2.235.1.1.500.11.32.39 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.39 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 39 - Description: Mezzanine card requesting power-on.
hwSwitchMezzBeingPoweredOn
- Relative OID:
2.235.1.1.500.11.32.41 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.41 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 41 - Description: Mezzanine card in power-on process.
hwSwitchMezzPoweredOn
- Relative OID:
2.235.1.1.500.11.32.43 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.43 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 43 - Description: Mezzanine card powered on.
hwSwitchMezzReqPowerOff
- Relative OID:
2.235.1.1.500.11.32.45 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.45 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 45 - Description: Mezzanine card requesting power-off.
hwSwitchMezzBeingPoweredOff
- Relative OID:
2.235.1.1.500.11.32.47 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.47 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 47 - Description: Mezzanine card in power-off process.
hwSwitchMezzAccess2V5Failure
- Relative OID:
2.235.1.1.500.11.32.51 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.51 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 51 - Description: Failed to read mezzanine card 2.5V voltage. (Generated)
hwSwitchMezzAccess2V5FailureDeassert
- Relative OID:
2.235.1.1.500.11.32.52 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.52 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 52 - Description: Failed to read mezzanine card 2.5V voltage. (Cleared)
hwSwitchMezzAccess3V3Failure
- Relative OID:
2.235.1.1.500.11.32.53 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.53 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 53 - Description: Failed to read mezzanine card 3.3V voltage. (Generated)
hwSwitchMezzAccess3V3FailureDeassert
- Relative OID:
2.235.1.1.500.11.32.54 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.54 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 54 - Description: Failed to read mezzanine card 3.3V voltage. (Cleared)
hwSwitchMezzAccess12VFailure
- Relative OID:
2.235.1.1.500.11.32.55 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.55 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 55 - Description: Failed to read mezzanine card 12V voltage. (Generated)
hwSwitchMezzAccess12VFailureDeassert
- Relative OID:
2.235.1.1.500.11.32.56 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.56 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 56 - Description: Failed to read mezzanine card 12V voltage. (Cleared)
hwSwitchMezzAccess1V5Failure
- Relative OID:
2.235.1.1.500.11.32.57 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.57 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 57 - Description: Failed to read mezzanine card 1.5V voltage. (Generated)
hwSwitchMezzAccess1V5FailureDeassert
- Relative OID:
2.235.1.1.500.11.32.58 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.58 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 58 - Description: Failed to read mezzanine card 1.5V voltage. (Cleared)
hwSwitchMezzAccess1VFailure
- Relative OID:
2.235.1.1.500.11.32.59 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.59 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 59 - Description: Failed to read mezzanine card 1V voltage. (Generated)
hwSwitchMezzAccess1VFailureDeassert
- Relative OID:
2.235.1.1.500.11.32.60 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.60 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 60 - Description: Failed to read mezzanine card 1V voltage. (Cleared)
hwSwitchMezzAccessStdby3V3Failure
- Relative OID:
2.235.1.1.500.11.32.61 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.61 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 61 - Description: Failed to read mezzanine card standby 3.3V voltage. (Generated)
hwSwitchMezzAccessStdby3V3FailureDeassert
- Relative OID:
2.235.1.1.500.11.32.62 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.62 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 62 - Description: Failed to read mezzanine card standby 3.3V voltage. (Cleared)
hwSwitchMezzAccessStdby1V8Failure
- Relative OID:
2.235.1.1.500.11.32.63 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.63 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 63 - Description: Failed to read mezzanine card 1.8V voltage. (Generated)
hwSwitchMezzAccessStdby1V8FailureDeassert
- Relative OID:
2.235.1.1.500.11.32.64 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.64 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 64 - Description: Failed to read mezzanine card 1.8V voltage. (Cleared)
hwSwitchMezzPSFault
- Relative OID:
2.235.1.1.500.11.32.65 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.65 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 65 - Description: Mezzanine card ps fault. (Generated)
hwSwitchMezzPSFaultDeassert
- Relative OID:
2.235.1.1.500.11.32.66 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.32.66 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSwitchMezzEvent 66 - Description: Mezzanine card ps fault. (Cleared)