2.235.1.1.500.11.34 hwSDEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.34 hwSDEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwSDEvent - Relative OID:
2.235.1.1.500.11.34 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 34
Object Definitions
Scalar objects and notifications defined under this node.
hwSDInstalled
- Relative OID:
2.235.1.1.500.11.34.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 1 - Description: SD card installed.
hwSDRemoved
- Relative OID:
2.235.1.1.500.11.34.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 3 - Description: SD card removed.
hwSDSRAIDArrayInvalid
- Relative OID:
2.235.1.1.500.11.34.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 5 - Description: SD card RAID lost. (Generated)
hwSDSRAIDArrayInvalidDeassert
- Relative OID:
2.235.1.1.500.11.34.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 6 - Description: SD card RAID lost. (Cleared)
hwSDRAIDRebuildStart
- Relative OID:
2.235.1.1.500.11.34.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 7 - Description: SD card starting to rebuild RAID.
hwSDRAIDRebuildFinish
- Relative OID:
2.235.1.1.500.11.34.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 9 - Description: SD card RAID rebuild completed.
hwSDRAIDRebuildFailure
- Relative OID:
2.235.1.1.500.11.34.11 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.11 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 11 - Description: SD card RAID rebuild failed. (Generated)
hwSDRAIDRebuildFailureDeassert
- Relative OID:
2.235.1.1.500.11.34.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.12 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 12 - Description: SD card RAID rebuild failed. (Cleared)
hwSDFault
- Relative OID:
2.235.1.1.500.11.34.13 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.13 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 13 - Description: SD card fault. (Generated)
hwSDFaultDeassert
- Relative OID:
2.235.1.1.500.11.34.14 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.14 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 14 - Description: SD card fault. (Cleared)
hwSDDetectCardFailure
- Relative OID:
2.235.1.1.500.11.34.15 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.15 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 15 - Description: SD card not detected. (Generated)
hwSDDetectCardFailureDeassert
- Relative OID:
2.235.1.1.500.11.34.16 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.34.16 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwSDEvent 16 - Description: SD card not detected. (Cleared)