2.235.1.1.500.11.7 hwRAIDCardEvent
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.11.7 hwRAIDCardEvent

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwRAIDCardEvent
  • Relative OID: 2.235.1.1.500.11.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 7

Object Definitions

Scalar objects and notifications defined under this node.

hwRAIDCardInstalled

  • Relative OID: 2.235.1.1.500.11.7.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 1
  • Description: RAID controller card installed.

hwRAIDCardRemoved

  • Relative OID: 2.235.1.1.500.11.7.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 3
  • Description: RAID controller card removed.

hwRAIDCardFault

  • Relative OID: 2.235.1.1.500.11.7.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 5
  • Description: RAID controller card fault. (Generated)

hwRAIDCardFaultDeassert

  • Relative OID: 2.235.1.1.500.11.7.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 6
  • Description: RAID controller card fault. (Cleared)

hwRAIDCardUncorrectableErr

  • Relative OID: 2.235.1.1.500.11.7.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 7
  • Description: RAID controller card MCE/AER error. (Generated)

hwRAIDCardUncorrectableErrDeassert

  • Relative OID: 2.235.1.1.500.11.7.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 8
  • Description: RAID controller card MCE/AER error. (Cleared)

hwRAIDCardOverTemp

  • Relative OID: 2.235.1.1.500.11.7.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 11
  • Description: RAID controller card overheating minor alarm. (Generated)

hwRAIDCardOverTempDeassert

  • Relative OID: 2.235.1.1.500.11.7.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 12
  • Description: RAID controller card overheating minor alarm. (Cleared)

hwRAIDCardAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.7.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 13
  • Description: Failed to read RAID controller card temperature. (Generated)

hwRAIDCardAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.7.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.14
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 14
  • Description: Failed to read RAID controller card temperature. (Cleared)

hwRAIDBBULowerVoltage

  • Relative OID: 2.235.1.1.500.11.7.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.15
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 15
  • Description: RAID controller card BBU undervoltage. (Generated)

hwRAIDBBULowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.7.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.16
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 16
  • Description: RAID controller card BBU undervoltage. (Cleared)

hwRAIDBBUFault

  • Relative OID: 2.235.1.1.500.11.7.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 17
  • Description: RAID controller card BBU fault. (Generated)

hwRAIDBBUFaultDeassert

  • Relative OID: 2.235.1.1.500.11.7.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 18
  • Description: RAID controller card BBU fault. (Cleared)

hwRAIDBBUNotPresent

  • Relative OID: 2.235.1.1.500.11.7.19
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.19
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 19
  • Description: RAID controller card BBU not detected.

hwRAIDBBUPresent

  • Relative OID: 2.235.1.1.500.11.7.21
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.21
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 21
  • Description: RAID controller card BBU detected.

hwRAIDCardOverTempMajor

  • Relative OID: 2.235.1.1.500.11.7.23
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.23
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 23
  • Description: RAID controller card overheating major alarm. (Generated)

hwRAIDCardOverTempMajorDeassert

  • Relative OID: 2.235.1.1.500.11.7.24
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.24
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 24
  • Description: RAID controller card overheating major alarm. (Cleared)

hwRAIDCardBBUOverTemp

  • Relative OID: 2.235.1.1.500.11.7.25
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.25
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 25
  • Description: RAID controller card BBU overheating minor alarm. (Generated)

hwRAIDCardBBUOverTempDeassert

  • Relative OID: 2.235.1.1.500.11.7.26
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.26
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 26
  • Description: RAID controller card BBU overheating minor alarm. (Cleared)

hwRAIDCardBBUAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.7.27
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.27
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 27
  • Description: Failed to read RAID controller card BBU temperature. (Generated)

hwRAIDCardBBUAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.7.28
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.28
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 28
  • Description: Failed to read RAID controller card BBU temperature. (Cleared)

hwRAIDCardCEHardFailure

  • Relative OID: 2.235.1.1.500.11.7.35
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.35
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 35
  • Description: RAID controller card health status degradation detected by PFAE. (Generated)

hwRAIDCardCEHardFailureDeassert

  • Relative OID: 2.235.1.1.500.11.7.36
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.36
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 36
  • Description: RAID controller card health status degradation detected by PFAE. (Cleared)

hwRAIDCardCommunicationLoss

  • Relative OID: 2.235.1.1.500.11.7.37
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.37
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 37
  • Description: The communication between the openUBMC and RAID controller card is faulty. (Generated)

hwRAIDCardCommunicationLossDeassert

  • Relative OID: 2.235.1.1.500.11.7.38
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.38
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 38
  • Description: The communication between the openUBMC and RAID controller card is faulty. (Cleared)

hwRAIDCardInitializationAbnormal

  • Relative OID: 2.235.1.1.500.11.7.39
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.39
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 39
  • Description: The initialization of RAID controller card is abnormal. (Generated)

hwRAIDCardInitializationAbnormalDeassert

  • Relative OID: 2.235.1.1.500.11.7.40
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.40
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 40
  • Description: The initialization of RAID controller card is abnormal. (Cleared)

hwRAIDCardAccessBoardIDFailure

  • Relative OID: 2.235.1.1.500.11.7.41
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.41
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 41
  • Description: Failed to obtain data of the board id for RAID Card. (Generated)

hwRAIDCardAccessBoardIDFailureDeassert

  • Relative OID: 2.235.1.1.500.11.7.42
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.42
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 42
  • Description: Failed to obtain data of the board id for RAID Card. (Cleared)

hwRAIDCardReplaced

  • Relative OID: 2.235.1.1.500.11.7.43
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.7.43
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwRAIDCardEvent 43
  • Description: Raid replaced.

Back to index